1. A/S Defrosting Mode (Heater defrost
→
Pause
→
Fan Delay)
INPUT
CONTROL OBJECT
CONTENTS
REMARKS
1. Defrosting Cycle
Heater
Defrosting
1) Comp, F/R-ICE/C Fan : OFF
R Damper : CLOSE
FD/RD-Heater : ON
2) Time limit
30 seconds : Heater is ON regardless of FD/RD-sensor
temperature right after defrosting start
30 minutes : in case of FD/rD-Error
50 minutes : in normal control state
3) If FD-sensor
≥
55.4
℉
, F Heater Defrosting is OFF
If RD-sensor
≥
55.4
℉
, R Heater Defrosting is OFF
Pause
Time : 7 minutes
Comp, F/R-ICE/C Fan, Damper, Heater etc. : OFF
Fan-Delay
1) Time : 5 minutes
Comp, C Fan : ON
F/R-ICE Fan, Damper, Heater : OFF
Pause
Fan-Delay
Heater
Defrosting
2. How to start
; In “Lock” mode, push “Frideg Set” button 5 times while pushing “Freezer Set”
button simultaneously.
3. How to proceed
1) same as normal defrosting
2) Heater is ON regardless of FD/RD-sensor temp. at first 30 seconds.
(Check of defrosting current)
4-4. Forced Defrosting Mode
1. Fan voltage of control mode
INPUT
CONTROL OBJECT
CONTENTS
REMARKS
1. F-Sensor
2. R-Sensor
1. F FAN, R-ICE FAN, C FAN
FAN
Freezer
R ICE
Condenser
Voltage
13 V
13 V
13 V
4-5. Fan Voltage of Control Mode
1. Comp
2. F/R-ICE/C Fan
3. FD/RD Heater
Содержание RFS-26D1 Series
Страница 1: ...JULY 2010 S M No RFS701D001...
Страница 5: ...4 2 EXTERNAL VIEWS 2 1 External Size...
Страница 7: ...6 Freezer Compartment Refrigerator Compartment 2 3 Cold Air Circulation...
Страница 14: ...13 4 2 Control of ice maker room 4 OPERATION AND FUNCTIONS CONTENTS 6 Ice maker actuation algorism...
Страница 28: ...27 5 WIRING DIAGRAM...
Страница 62: ...61 9 6 Dispenser Water Flow...