5. DISASSEMBLING AND TERATMENT
1) Remove dust box assembly(1) from body assembly(5).
2) Lift handle(2) up cover assembly(4) then unscrew 6 screws(3).
4) Remove cover assembly(4) from body assembly(5).
5) Remove cord reel assembly(8), case motor assembly(6) and motor assembly(6) from body assembly(5).
1) Check dust leakage between dust box(1) and body assembly(2)
(Cause of defective motor).
2) Check inlet(9) of body assembly(2) clogged with dust
(Cause of low suction power).
3) Check connection between wire connector(6) of cord reel and PCB
(Cause of malfunction).
4) Check connection between wire connector(5) of motor and PCB
(Cause of malfunction).
5) Check PCB circuit, ON/OFF switch(8) and rotary volume(7)
(Cause of of malfunction).
5-1. CLEANER ASSEMBLY