25
1. CIRCUIT CHECK PROCEDURE
1. Low Voltage Transformer check
• The low voltage transformer is located on the P.C.B.
• Measuring condition: input voltage : 230V/Frequency : 50Hz
2. Voltage check
• Key check point
• Check method
PRINTED CIRCUIT BOARD
NO
CHECK POINT
REMARK
1
IC 1 PIN 2, 21, 30, 34
-5 VDC
2
IC 1 PIN 35
3
IC 1 PIN 31 OR 32
NOTE :
Each measure point must be measured with GND point.
NOTE :
1. Refer to Circuit Diagram (point 4).
2. Secondary side voltage of the low voltage transformer changes in proportion to fluctuation of power source voltage.
3. The allowable tolerance of the secondary voltage is within ± 5% of nominal voltage.
0V
-5V
0V
-5V
Terminal Voltage
4-7
LOAD
AC 12.6 V
NO LOAD
AC 14.7 V
NO
MEASURE POINT
WAVE FORM
REMEDY
REMARK
1
MP1
DC -5V±0.25V
Replace VL1, EC1
NO LOAD
2
MP2
DC -12V±2.0V
Replace EC2, D12, 13, 14
NO LOAD
T:20ms(50Hz)
T:250ns(4MHz)
Содержание N230S
Страница 5: ...4 EXTERNAL VIEW 1 OUTER DIMENSION 539 406 300...
Страница 25: ...24 WIRING DIAGRAM...
Страница 27: ...26 Measure Point MP1 MP2...
Страница 29: ...28 2 PCB CIRCUIT DIAGRAM...