71
• situation : PCB shows "E3".
cause)
☞
FAN MOTOR can not work.
countermeasures)
☞
Replace the Fan Motor.
part name
checking results
repair method
disassemble process of Fan Motor
FAN MOTOR
fan motor failure
replace
fan motor
1
Disassemble Duct Cover As from Duct B As
(Screw 4EA)
2
Disassemble FAN AS From Duct Cover As
(Fixed by 8mm NUT)
3
Disassemble the FAN MOTOR(SCREW 3EA)
parts
Control time
MOTOR
15 sec On, 5sec Off
DRAIN MOTOR
Continous working
FAN MOTOR
Continous working
DRY HEATER
95°C On, 105°C Off
INLET VALVE
30sec On, 5sec Off
Remarks) control times of each parts during dry process
DUCT COVER
AS
Fixed By 8mm NUT
Содержание KUD-UD122RF
Страница 10: ...4 Parts list by ass y 8 1 PANEL F AS 1 UD123X SERIES...
Страница 12: ...10 1 PANEL F AS 2 UD124X SERIES...
Страница 16: ...14 3 CABINET F ASSY C11 C10 C07 C12 C03 C06 C09 C08 C05 C04 C01 C16 C02 C13 C14 C15...
Страница 18: ...16 4 CABINET ASSY...
Страница 20: ...18 5 BASE U AS...
Страница 22: ...20 6 TUB ASSY...
Страница 24: ...22 7 DUCT B AS DUCT PIPE AS...
Страница 78: ...76 1 Structure of BLDC Motor 7 HEATER BLDC MOTOR 2 Power Transmission System of BLDC Motor...