2
4
PRINTED CIRCUIT BOARD
1. CIRCUIT CHECK PROCEDURE
1. Low voltage transformer check
The low voltage transformer is located on the P.C.B.
Measuring condition: Input voltage: 230V/Frequency : 50Hz
2. Voltage Check
- Key check point
- Check method
NOTE
1. Refer to Circuit Diagram.
2. Secondary side voltage of the low voltage transformer changes in proportion to fluctuation of power source
voltage.
3. The allowable tolerance of the secondary voltage is within ± 5% of nominal voltage.
NOTE
Each measure point must be measured with GND points.
Terminal Voltage
(4,5) -6 or (7, 8) -6
LOAD
AC 14 V
NO LOAD
AC 17 V
NO
CHECK POINT
REMARK
1
IC 1 PIN 5
5 VDC
2
IIC 1 PIN 8
3
IC 1 PIN 19 OR PIN 20
NO
MEASURE POINT
WAVE FORM
REMEDY
REMARK
1
MP1
DC 5V ±0.25V
Replace Q8, R28, ZD3, C2, EC1
NO LOAD
2
MP2
DC 15V ±3.0V
Replace EC3, D11, D12, D13, C9
NO LOAD
T
T:20ms(50Hz)
5V
0V
T
T:250ns(4MHz)
5V
0V