1
3
6. To remove high voltage capacitor.
1) Remove the screw which secure the grounding ring
terminal of the H.V. diode and the capacitor holder.
2) Remove the H.V. diode from the capacitor holder.
3) Reverse the above steps for reassembly.
◆
High voltage circuit wiring
7. To remove magnetron.
1) Remove the screw which secure the magnetron.
2) Remove the magnetron.
3) Reverse the above steps for reassembly.
NOTE : Never install the magnetron without the metallic gasket plate which is packed with each magnetron to
prevent microwave leakage. Whenever repair work is carried out on magnetron, check the microwave
leakage. It shall not exceed 4mW/cm
2
for a fully assembled oven with door normally closed.
Metallic
gasket
plate
Magnetron
antenna
Cooling fin
Filament
terminal
<MAGNETRON>
Wave guide
Magnetron antenna
Metallic gasket plate
Содержание KOR-6LZB
Страница 1: ...Service Manual Model KOR 6LZB Microwave Oven May 2010...
Страница 24: ...23 WIRING DIAGRAM S N 3513511800...
Страница 26: ...25 Measure Point MP1 MP2 GND...
Страница 28: ...27 2 PCB CIRCUIT DIAGRAM...