4. Method to reduce the gap between the door seal and the oven front surface.
(1) To reduce gap located on part ‘A’
• Loosen two screws on the stopper hinge top, and then
push the door to contact the door seal to the oven front sur-
face.
• Tighten two screws.
(2) To reduce gap located on part ‘B’
• Loosen two screws on the stopper hinge under, and then
push the door to contact the door seal to the oven front sur-
face.
• Tighten two screws.
(3) To reduce gap located on part ‘C’
• Loosen the screw on the interlock switch assembly located
the top of the oven body.
• Draw the interlock switch assembly inward as possible to
engage with the hook on the door bottom.
• Tighten a screw.
(4) To reduce gap located on part ‘D’
• Loosen the screw on the interlock switch assembly located
the bottom of the oven body.
NOTE : A small gap may be acceptable if the microwave leakage does not exceed 4mW/cm