32
PRINTED WIRING BOARD
1.CIRCUIT CHECK PROCEDURE
1) Low voltage transformer (DMR-984FS) check.
The low voltage transformer is located on the P.C.B.
Measuring condition:
Input voltage: 230VAC/50Hz
2) Voltage Check
• Key check point (1~5: Micom Pin, 6:Display Pin)
• CHECK METHOD
Terminal
1-3
6-7
7-8
9-10
Voltage
230.0V
9 VAC
9 VAC
2.3 VAC
1
9
8
7
6
10
3
5
NOTE 1 : Secondary side voltage of the low voltage transformer changes in proportion to fluctuation of power
source voltage.
NOTE 2 : The allowable tolerance of the secondary voltage is within ± 5% of nominal voltage.
NO.
CHECK POINT
REMARK
1
PIN 63, 64
+5VDC±5%
2
PIN 29, 32, 62
0V
3
PIN 28
+5VDC±5%
4
PIN 45
5
PIN 30, 31
6
PIN 1, 25
2.6VAC (Display filament voltage)
NO.
CHECK POINT
REMARK
1
+5VDC
Replace Q3, ZD3, R26, C10
2
+12 VDC
Replace D7, D8, EC2, EC3, C14, C11
3
-24 VDC
Replace D9, D10, EC4, EC5, C15
NOTE :
The marks of the above corresponding voltages (+5, +12, -24VDC)are written on the PCB.
Each measuring points must be measured with GND points.
0V
+5VDC
T
0V
5V
T
T=0.25us (4.0MHz)
T: 20 ms (50 Hz)