MEASUREMENT AND TEST
1. MEASUREMENT OF THE MICROWAVE POWER OUTPUT
Microwave output power can be checked by indirectly measuring the temperature rise of a certain amount of water exposed to
the microwave as directed below.
PROCEDURE
1. Microwave power output measurement is made with the microwave oven supplied at rated voltage and operated at its
maximum microwave power setting with a load of 1000 ± 5cc of potable water.
2. The water is contained in a cylindrical borosilicate glass vessel having a maximum material thickness of 3 mm and an outside
diameter of approximately 190 mm.
3. The oven and the empty vessel are at ambient temperature prior to the start of the test. The initial temperature of the water is
10 ± 2 °C (50 ± 3.6 °F). It is measured immediately before the water is added to the vessel. After addition of the water to the
vessel, the load is immediately placed on the center of the shelf, which is in the lowest normal position.
4. Microwave power is switched on.
5. Heating time should be exactly A seconds.
(Refer to table as following).
Heating time is measured while the
microwave generator is operating at
full power. The filament heat-up time
for magnetron is not included.
6. The initial and final temperature of water is selected
so that the maximum difference between the ambient and
final water temperature is 5K.
7. The microwave power output P in watts is calculated
from the following formula:
•
T is difference between initial and ending temperature.
•
t is the heating time.
The power measured should be B (Refer to SPECIFICATIONS) W ± 10.0 %.
Heating time for power output
A (second)
70
64
60
56
52
49
47
44
42
40
38
B (W )
600
650
700
750
800
850
900
950
1000
1050
1100
M icrow ave em ission test should be perform ed after adjusting interlock m echanism . If the m icrow ave em ission
exceed 4m W /cm
2
, readjust interlock m echanism .
NOTE
P = 4187
T/t
Содержание KOG-39B50S
Страница 5: ... EXTERNAL VIEW 1 OUTER DIMENSION Fig2 Side view Fig1 Front view ...