1. CIRCUIT CHECK PROCEDURE
1) Low voltage transformer (DMR-814FS) check.
The low voltage transformer is located on the P.C.B.
Measuring condition: Input voltage : 230V
Frequency: 50Hz
2) Voltage Check
Key check point (MICOM PIN)
CHECK METHOD
NO.
CHECK POINT
REMARK
1
PIN 21,24,32,33 OR 34
-5VDC
2
PIN 48
-27VDC
3
PIN 44
4
PIN 18 OR 19
5
DP1 PIN 1& 25
2.6VAC (DISPLAY FILAMENT VOLTAGE)
1
MP1
-5V DC
Replace Q4, EC2
2
MP2
-16V DC
Replace R6, EC3
3
MP3
-24V DC
Replace D12, D13, EC4
C-D
-19VDC
-24VDC
E-F
2.1VDC
2.2VAC
41
NO.
MEASURE POINT
WAVE FORM
REMARK
Voltage
Terminal
LOAD
NO LOAD
PRINTED CIRCUIT BOARD
NOTE 1 : Secondary side voltage of the low voltage transformer changes in proportion to fluctuation of power
source voltage.
NOTE 2: The acceptable tolerance of the secondary voltage is within ±5% of nominal voltage.
NOTE: Each measure point must be measured with GND points.
T:20ms (50HZ)