18
NOTE : Microwave emission test should be performed after adjusting interlock mechanism. If the
microwave emission exceed 4m W/cm
2
, readjust interlock mechanism.
(2) Secondary interlock switch and interlock monitor switch
When the door is closed, the hook pushes the push lever down ward, and push lever presses the button of the
interlock monitor switch to bring it under “off’, condition and presses the button of the secondary interlock switch
to bring it under “on”, condition.
Adjustment 2
Interlock monitor switch
When the door is closed, the interlock monitor switch should be opend before other switches close.
When the door is closed, the interlock monitor switch should be closed after other switches open
Secondary interlock switch
The movant of the switch button should exceed 1.2mm measured at the top of the button.
(3) Adjustment steps
a) Loosen the two mounting screws.
b) Adjust interlock switch assembly position.
c) Confirm the gap(1.2mm) described above.
d) Make sure that push lever moves smoothly adjustments is completed.
e) Completely tighten the two mounting screws.
(4) Interlock switch replacement
Whenever safety interlock switches are replaced:
1) Refer to the following diagram.
2) Check the connection of monitor switch after replacement.
3) Perform the electrical continuity check of interlock switches and microwave emission test mentioned in this
manual.
SYMBOL
COLOR
RD
RED
BL
BLUE
WH
WHITE
GY
GRAY
BK
BLACK
Содержание KOG-366T0S
Страница 1: ...Service Manual Microwave Oven Model KOG 366T0S DAEWOOELECTRONICS CO LTD OVERSEASSERVICEDEPT...
Страница 22: ...21 WIRING DIAGRAM GERMANY Fig 1...
Страница 23: ...22 WIRING DIAGRAM Fig 1 1...
Страница 46: ...45 2 P C B Circuit Diagram...
Страница 47: ...46 3 COMPONENT INFORMATION 1 Transistor NPN Type 2 Diode and Zener Diode D1 16 ZD1 6...
Страница 48: ...47 4 PRINTED CIRCUITS BOARD...
Страница 49: ...48...
Страница 54: ...53 3 Main Unit...