5. BLOWER MOTOR AND CONVECTION MOTOR
1) Remove a connector from the motor.
2) Measure resistance between two terminals like as following figure.
3) Reading of blower motor is 60
Ω
and convection motor is 270
Ω
.
4) It is normal to stop convection motor smoothly, when door is open during convection mode.
=> You can see the motion of convection motor,
6. HEATER (TOP HEATER, REAR HEATER, HALOGEN HEATER)
1) Remove a connector from the heater
2) Measure resistance between two terminals like as following figure.
3) Normal readings of top heater, rear heater and halogen heater are 36
Ω
, 36
Ω
, 23
Ω
.
4) The oven should be cooled enough to measure resistance of the heater.
7. NOISE FILTER
1) Remove a connector from the noise filter.
2) Check each continuity of N-N and L-L terminal like as following figure.
3) It should be normal to keep continuous continuity.
L-L
N-N
BLOWER MOTOR
CONVECTION MOTOR
TOP HEATER
REAR HEATER
HALOGEN HEATER
Measuring
point
Measuring
point
Measuring
point
Measuring
point
Measuring
point