Daewoo HEA1574 Скачать руководство пользователя страница 7

Safety Cut – Out

Warning: This appliance is fitted with a built in safety cut-out, if the 

cut-out is activated the unit stops working, unplug the heater from the 

mains and check that the air intake area is not blocked or covered. 

Leave for an hour to cool and reset before plugging back into the 

mains.

Technical Data

Voltage 

 

220-240V ~ 50Hz

Rated power  

1750-1950W 

Model Number 

HEA1574

Electrical Connections

This appliance is fitted with a fused three-pin plug to BS 1363. If the 

plug has to be removed, it should be cut off and carefully disposed of 

immediately. To avoid a possible shock hazard, do not insert the dis-

carded plug into a mains socket.

Fitting a new plug

The mains lead must be connected as shown below. The wires are 

coloured with the following code - Brown wire = Live (L), Blue wire = 

Neutral (N), 

Green & Yellow = Earth (E).

Connect Green & 

Yellow to Earth (E)

Connect Blue to 

Neutral (N)

Connect Brown to 
Live (L

)

Ensure the outer sheath of the 

mains lead is securely held by 

the cable clamp

Содержание HEA1574

Страница 1: ......

Страница 2: ...rrectly Do not use this heater with an extension cable Check that the voltage indicated on the data plate corresponds with that of the local network before connecting the appliance to the mains power...

Страница 3: ...ance on a solid level non flammable surface Do not use this appliance outdoors It is imperative to unplug the power cord after the appliance has been used before it is cleaned and whilst being repaire...

Страница 4: ...ot push objects into any openings as damage to the appliance and or electric shock may occur The appliance should not be installed in areas which have a fire risk such as garages stables or wooden she...

Страница 5: ...Description of parts Controls Real Flame Effect Door Controls behind door Heat Outlet Thermostat Dimmer ON OFF Switch...

Страница 6: ...ightened using the dimmer control Hint on setting the correct temperature Set the heater to the desired heat setting as above Rotate the Thermostat to the maximum position and allow the room to warm u...

Страница 7: ...l Connections This appliance is fitted with a fused three pin plug to BS 1363 If the plug has to be removed it should be cut off and carefully disposed of immediately To avoid a possible shock hazard...

Страница 8: ...minal marked E or coloured Green Check that there are no cut or stray strands of wire inside the plug Use a 13 Amp BS 1362 fuse only use BSI or ASTA approved fuses If you are in any way unsure which p...