Daewoo HEA1403 Скачать руководство пользователя страница 6

 

Electrical Connections 

 

This appliance is fitted with a fused three-pin plug to BS 1363. If the plug has 
to be removed, it should be cut off and carefully disposed of immediately. To 
avoid a possible shock hazard, do not insert the discarded plug into a mains 
socket. 

 
 

Fitting a new plug 

The mains lead must be connected as shown below. The wires are coloured with 
the following code - 

Brown wire = Live (L), Blue wire = Neutral (N).

 NB

 no 

connection must be made to the Earth (E) terminal. 
 
 

 

 

 

 

 

 

 

  The Blue wire must be connected to the terminal marked N or coloured Black.  

  The Brown wire must be connected to the terminal marked L or coloured Red. 

  The Green and Yellow wire must be connected to the terminal marked E or coloured 

Green.  

  Check that there are no cut or stray strands of wire inside the plug.  

  Use a 13 Amp BS 1362 fuse, only use BSI or ASTA approved fuses.  

  If you are in any way unsure which plug or fuse to use, always refer to a qualified 

electrician. 

  After replacing or changing a fuse on a moulded plug, the cover must be refitted to 

the plug; the appliance must not be used without a fuse cover. 

 

WARNING: Do not wrap the cord around the heater for storage. 

 
 
 
 

Connect 
Brown to 
Live (L) 

Connect 
Blue to 
Neutral (N) 

Ensure the outer sheath of the mains 
lead is securely held by the cable clamp 

Содержание HEA1403

Страница 1: ......

Страница 2: ...e corresponds with that of the local network before connecting the appliance to the mains power supply Close supervision is required when using this appliance near children Never leave this appliance...

Страница 3: ...liance with a damaged plug or cord after a malfunction or after being dropped or damaged in any way Regular periodic checks should be carried out on the mains cable to ensure no damage is evident Shou...

Страница 4: ...ill quickly disappear It is the coating applied to the heating elements to prevent any corrosion during transit Description of Controls 1 Air Intake 2 On Off Fan Heat Switch 3 Thermostat 4 Indicator 5...

Страница 5: ...y The Thermostat will now maintain the room temperature if necessary further increasing or decreasing the thermostat control may be required to fine tune the ideal room temperature Return the on off f...

Страница 6: ...loured Black The Brown wire must be connected to the terminal marked L or coloured Red The Green and Yellow wire must be connected to the terminal marked E or coloured Green Check that there are no cu...

Страница 7: ...Technical Data Voltage 220 240V 50Hz Rated power 2000 W Dimensions 265mm H x 225mm W x 125mm D Weight 0 9kg Model Number HEA1403...

Страница 8: ...nal heat output elmax 0 012 fan motor KW Type of heat output room temperature control select one At minimum heat output elmin 0 012 fan motor KW single stage heat output and no room temperature contro...

Страница 9: ......

Отзывы: