8-8-2. Inverter Control Mode
1) Frequency Mode
Controls the compressor speed through a frequency signal sent to the Inverter.
The frequency signal is a digital square wave, with 0 to +5V voltage amplitude and defined range as described ahead.
The duty cycle must be from 30% to 70%.
< Frequency signal >
2) Compressor speed
Compressor speed will follow the frequency signal, according to the relation described bellow.
< Relation between Inverter frequency and compressor rotation >
1,600
50.1 to 53.3
30 x Hz
53.4 to 150
hysteresis
105 to 111
hysteresis
130 to 132
hysteresis
136.6 to 138.6
4,500
> 150
0
0 to 50
Comp Speed
(rpm)
Input Signal
(Hz)
3) In this refrigerator, input frequency signals are used as below.
Other conditions
Ambient Temperature
Initial Power connected
Weak-Cool
Super FRZ
Super REF
Normal condition
-
122 Hz
85 Hz
122 Hz
Input
Frequency
3660 rpm
2550 rpm
below 35
℃