DISASSEMBLING PROCEDURE
NO
DISASSEMBLING PROCEDURE
1
3
2
- Insert (-) screw driver into bottom hole of
dispenser button guide.
Pull up forward to remove the guide.
(Be careful not to damage guide surface.)
- Remove Micro switch.
2) How to Check Micro Switch
CRITERION
- GOOD :
- DEFECTIVE :
Change Micro Switch.
PARTS
HOW TO CHECK
SPEC. NAME
: VP333A-OD-8
VOLTAGE
:125V,3A
8-3. Dispenser Micro Switch
1) Disassembling Procedure
- Check both terminals
(red circle) with a Multi Tester
(Tester Mode : Resistance.
Tact Switch
(Blue Circle)
Terminals
(Red circle)
Tester Result
(Resistance Mode)
ON (Close)
Connected
Some Value
OFF (Open)
Disconnected
No value (0)
- Check Micro Switch.
- Separate wire connectors
from Micro Switch.