7. Defrosting Cycle
OPERATION AND FUNCTIONS
25
INPUT
Control Object
1. Total comp. work time
2. Comp. work rate
3. RT temperature
4. Total door open time
1. Defrosting Mode
CONTENTS
1. Conditions to start defrosting cycle
1)
Total comp. work time : 6, 8, ........ 24 hours.
2)
Total door open time : 3 minutes
(Any door - F or R - open time is over 3 minutes.)
3)
Total time of [comp. ON + comp. OFF] : 60 hours
4) Any error mode : R1, F1, D1, F3, RT/S, Door-switch
2. Conditions to start defrosting mode
1) The mode starts with the following conditions ;
Any error happens when total comp. work time is 6 or 8....... or 24hours.
Total door open time is over 3 minutes.
(Any door - F or R - open time is over 3 minutes.)
2) Defrosting mode starts unconditionally as long as total comp. work time is 24 hours,
even if the above conditions(
~
) are not satisfied.
3) Defrosting mode starts immediately as long as total time of [comp. ON + comp. OFF] is
over 60 hours, even if the above 1) and 2) conditions are not satisfied.
Remark
Содержание FRS-T20FA Series
Страница 3: ...2 1 EXTERNAL SIZE FRS T20DA EXTERNAL VIEWS ...
Страница 4: ...3 FRS T20FA EXTERNAL VIEWS ...
Страница 6: ...5 3 Cold Air Circulation Freezer Compartment Refrigerator Compartment EXTERNAL VIEWS ...
Страница 42: ...41 RSCR TYPE 1 WIRING DIAGRAM DIAGRAM ...
Страница 43: ...42 DIAGRAM CSR TYPE ...
Страница 44: ...43 DIAGRAM 2 CIRCUIT WIRING DIAGRAM Main PCB ...
Страница 45: ...44 FRONT PCB DIAGRRAM DIAGRAM ...
Страница 52: ...CABINET 51 EXPLODED VIEW 1 FRS T20DA ...
Страница 53: ...EXPLODED VIEW MECH ROOM 52 ...
Страница 54: ...EXPLODED VIEW R Room 53 ...
Страница 55: ...54 EXPLODED VIEW F ROOM ...
Страница 56: ...55 EXPLODED VIEW F Door ...
Страница 57: ...56 EXPLODED VIEW R Door ...
Страница 64: ...CABINET 63 EXPLODED VIEW 3 FRS T20FA ...
Страница 65: ...EXPLODED VIEW MECH ROOM 64 ...
Страница 66: ...EXPLODED VIEW R Room 65 ...
Страница 67: ...66 EXPLODED VIEW F ROOM ...
Страница 68: ...67 EXPLODED VIEW F Door ...
Страница 69: ...68 EXPLODED VIEW R Door ...