23
TROUBLE SHOOTING
PROBLEM
WATER
SUPPLY IS
NOT
STOPPED.
CHECK POINT
Does the water supply
continue while the power
is turned off?
Does the water supply start
as soon as you press the
power switch?
Operate the washer after
setting the water level to
“HIGH”
Does the water supply
continue after the water
reaches to the “HIGH”
level?
Is the air tube of water
level switch kinked or
deformed?
CAUSE
SOLUTION
Change the water inlet
valve.
The water inlet valve is
defective.
The triac of P.C.B is
defective.
Change the P.C.B
ASS’Y.
Normal operation.
Change the air tube.
Air tube is defective.
Change the pressure
switch.
Pressure switch is
defective.
PROBLEM
THE
PULSATOR
DOES NOT
ROTATE EVEN
IF THE WATER
IS SUPPLED.
CHECK POINT
Does the motor operate after
finishing water supply?
Does the motor make
operating sound?
Is the connection
condition of capacitor
terminal good?
Does pulsator rotate in
only one direction?
Is the motor coil
disconnected?
Is the V-belt worn out?
The triac of P.C.B is
defective.
Motor is defective.
Improper connection
V-belt is defective.
Change the P.C.B
ASS’Y.
Normal
Change the motor.
Connect the terminal
properly.
Change the V-belt.
Change the motor.
CAUSE
SOLUTION
YES
YES
YES
NO
NO
YES
YES
NO
YES
YES
YES
NO
YES
NO
NO
NO
NO
NO
YES
Concerning Washing
Содержание DWF-513W
Страница 29: ...APPENDIX 28 PCB ASS Y Wiring Diagram ...
Страница 30: ...29 PARTS DIAGRAM Parts Diagram ...
Страница 31: ...30 PARTS DIAGRAM ...
Страница 32: ...31 PARTS DIAGRAM ...
Страница 33: ...32 PARTS DIAGRAM ...