8. PRESENTATION OF THE P.C.B ASS’Y
27
PCB ASS’Y
MESSAGE
CAUSE
SOLUTION
Improper installation of drain hose.
The drain hose is blocked up by foreign
matter.
Drain motor is inferior.
The water tap is closed.
The water inlet filter clogged.
It passes over the 60 minutes, yet it doesn’t
come to assigned water level.
Wash loads get uneven during spin.
Poor installation of the unit.
The lid is opened.
The safety switch is inferior.
The load sensing is inferior. After the load
sensing operates about 7 seconds, the
message is displayed during 0.5 second
and water level is always fixed ‘high’.
The water level sensing is inferior.
Install drain hose properly.
Remove foreign matter from drain hose.
Change drain motor.
Open the water tap.
Clean the water inlet filter.
Fully open the water tap and
Check the water pressure.
Re-set wash loads evenly.
Proper installation.
Close the lid.
Change the safety switch.
Change the P.C.B. ASS’Y.
Check the water level sensor and the
contact part of the connector.
Concerning Error Message
Содержание DWF-513W
Страница 29: ...APPENDIX 28 PCB ASS Y Wiring Diagram ...
Страница 30: ...29 PARTS DIAGRAM Parts Diagram ...
Страница 31: ...30 PARTS DIAGRAM ...
Страница 32: ...31 PARTS DIAGRAM ...
Страница 33: ...32 PARTS DIAGRAM ...