18
TROUBLESHOOTING GUIDE
Problem
Error Code
Possible Cause
Solutions
The machine
fills overtime.
“Spin” LED flickers.
1. The water tap is not open.
2. The drain hose is put down.
3. The water inlet valve is
damaged.
1. Open the water tap.
2. hook up the hose.
3. Change the water inlet
valve.
There is a Door
lock alarm.
“Rinse” LED flickers.
1. The door is not locked well.
2. garment is caught between
the door and the seal.
3. The door lock is damaged.
1. Lock the door well.
2. Put the garment into the
drum.
3. Change the door lock.
The machine
drains overtime.
“Rinse” and “Spin”
LEDs flicker.
1. The drain hose is squashed
or kinked.
2. The drain pump filter is
block.
3. The drainage system pipes
are blocked.
1. Check the drain hose.
2. Clean the filter.
3. Check the drainage system
and clean it.
Water overflows
the machine.
/ Water sensor
works abnormal.
“Washing” LED
flickers.
1. The water inlet valve is
damaged.
2. The connection between the
water sensor and wire is not
secure.
3. The water sensor is
damaged.
1. Change the water inlet.
2. Check the connection and
ensure it is secure.
3. Change the water sensor.
The motor does
not work.
“Washing” and “Spin”
LEDs flicker.
1. The connection between the
motor and wire is not secure.
2. The motor is protected
because of over-heat.
3. The motor is damaged.
1. Check the connection and
ensure it is secure.
2. Check if the machine is
overloaded. Switch off the
machine, and retry when the
motor becomes cool.
3. Change the motor.
There is a
heating tube
fault.
“Washing” and
“Rinse” LEDs flicker.
1. The connection between the
heating tube and wire is not
secure.
2. The heating tube is
damaged.
1. Check the connection and
ensure it is secure.
2. Change the heating tube.
There is a
temperature
sensor fault.
“Washing”, “Rinse”
and “Spin” LEDs
flicker.
1. The connection between the
temperature sensor and wire
is not secure.
2. The temperature sensor is
damaged.
1. Check the connection and
ensure it is secure.
2. Change the temperature
sensor.
NOTE :
Technical repairs should only be undertaken by a suitably qualified person.
DWD-GM1011_영국향.indd 19
2013-09-23 오전 11:42:02