41
5) TROUBLE SHOOTING OF DRY SYSTEM
◈
◈
HEATER DRY
Function : heating the air during dry
◎
FAILURE MODE :
*
"H7" - The air cannot be heated to 10
℃
during 2 min.
◎
CHECKING METHOD :
*
Check the resistance of heater coil and replace with new one.
◈
◈
Thermistor
Function : sensing the air temperature.
◎
FAILURE MODE :
*
The air cannot be heated even though water is supplied.
*
"H1" - shot or cut-off
*
"H3" - air temp. is reached over 150
℃
◎
CHECKING METHOD :
*
Check the resistance of thermistor, replace with new one.
◈
◈
FUSE TEMPERATURE
function : protecting from the fine hazard or overheating, if the temp., rises over 128
℃
, power supply will be cut-off.
◎
Pictures
◎
FAILURE MODE : Dry is not performed.
◎
CHECKING METHOD : Check if fuse is short, and replace with new one.
FIXED BY
WASHER
+
SCREW
Содержание DWD-1211RT
Страница 1: ...JUL 2005 Model DWD 1211RT DWD 1221RT DWD 1223RT WDE1211001 DRUM WASHING MACHINE ...
Страница 11: ...7 BASE U AS 8 EA TUB AS 29 EA CABINET AS 10 EA DUCT B AS A DUCT PIPE 23 EA ...
Страница 15: ...11 3 THE EXPLODED VIEW OF CABINET F ASSEMBLY ...
Страница 18: ...14 5 THE EXPLODED VIEW OF TUB ASSEMBLY ...
Страница 20: ...16 6 THE EXPLODED VIEW OF DUCT B AS A DUCT PIPE ASSEMBLY WASH ...
Страница 58: ...2005 05 DRUM WASHING MACHINE 본사 서울마포구아현동686 소비자상담실 대표 360 8282 http www dwe daewoo co kr ...