Daewoo DWC-055RL Скачать руководство пользователя страница 13

12

FUNCTION

FAN MODE

Push the ‘MODE’ button until
‘FAN’ lamp lights.

ON/OFF ENERGY SAVE

Push the ‘ENERGY SAVE’
button.

TURBO MODE

Push the ‘MODE’ button until
‘TURBO’ lamp lights.

OFF TIMER

Push the ‘TIMER/CANCEL’
button when unit is working.
(REMOCON ONLY)

OPERATION

1. The Fan works only.
2. In this mode, the unit circulate room air.
3. Fan speed can be changed.

1. Desired temperature is changed as

follows by pushing ‘ENERGY SAVE’
button.

2. When the ‘ENERGY SAVE’ button is

pushed, the fan speed goes to ‘Low’

3. When the ‘ENERGY SAVE’ function

is canceled by pushing ‘ENERGY
SAVE’ button once again, the
desired temperature is return to the
former desired temperature.

1. Fan speed is set to ‘HIGH’ and

desired temperature to 18°C (64°F). 

1. Timer is set to as follows by pushing

“TIMER/CANCEL” button.
(1hr

2hr

3hr

4hr

5hr

6hr

8hr

10hr

12hr

16hr

20hr

24hr

cancel)

2. Unit is off after timer is over.

3. If you want to cancel timer, push this

button again at any time.

DISPLAY

1. Current room temperature is

displayed.

2. ‘FAN’ lamp lights.

1. Current room temperature is

displayed.

2. ‘ENERGY SAVE’ lamp lights.

1. Current room temperature is

displayed.

2. ‘TURBO’ lamp lights.

1. ‘TIMER’ lamp lights.
2. Set time is displayed.

3. After a few seconds, display is

changed to current room temprature. 

ENERGY

SAVE

ENERGY

SAVE

MODE

MODE

TIMER/

CANCEL

MODE

MODE

or

or

or

hr

‘ENERGY SAVE’

ON

‘ENERGY SAVE’

OFF

1hr

+1

°

C

+1

°

C

-2

°

C

FAN

ROOM

TEMP.

TEMP

DESIRED

TEMP.

TIMER

ENERGY

SAVE

TURBO

COOLING

FAN

ROOM

TEMP.

TEMP

DESIRED

TEMP.

TIMER

ENERGY

SAVE

TURBO

COOLING

FAN

ROOM

TEMP.

TEMP

DESIRED

TEMP.

TIMER

ENERGY

SAVE

TURBO

COOLING

FAN

ROOM

TEMP.

TEMP

DESIRED

TEMP.

TIMER

ENERGY

SAVE

TURBO

COOLING

FAN

ROOM

TEMP.

TEMP

DESIRED

TEMP.

TIMER

ENERGY

SAVE

TURBO

COOLING

Содержание DWC-055RL

Страница 1: ... TYPE ROOM AIR CONDITIONER W1 R C US LISTED UL and CUL listed Please read carefully and thoroughly this manual before operating the unit If you still have any difficulties or problems consult your dealer for help or ELECTRONICS Please keep this manual well S N 3113905610 ...

Страница 2: ...t 7 Wait at least 3 minutes before restarting the unit or in the case of power failure If you turn on the unit within 3 minutes after power off this can cause damage to the unit 8 If the air conditioner is operated without an air filter dust is not removed from the air and resultant accumulation in the unit may lead to a failure Do not forget to install the air filter 9 The air filter should be cl...

Страница 3: ...PARE WINDOW FOR INSTALLATION STEP3 PLACING UNIT IN WINDOW STEP4 INSTALL SASH BRACKET STEP5 SECURE WINDOW SHUTTER STEP6 RECHECK INSTALLATION STEP7 RECHECK THE ENTIRE INSTALLATION 3 NAMES OF MAJOR COMPONENTS 8 4 OPERATION INSTRUCTIONS 9 14 DISPLAY REMOTE CONTROL HOW TO INSERT BATTERIES 5 GENERAL INFORMATION 15 CHANGING AIR FLOW DIRECTION AIR FLOW AROUND UNIT 6 CARE AND MAINTENANCE 16 AIR FILTER CLEA...

Страница 4: ...other materials for the job Study the illustrations in these instructions to become familiar with important details of the installation process Read the Use Care manual to become familiar with the operation of your room air conditioner After installing the unit re read these instructions to make sure you have completed each step and all parts are fastened in place for a secure installation For bes...

Страница 5: ...quately grounded or protected by a fuse or circuit breaker have a qualified electrician install the proper oulet according to the National Electric Code and applicable local code WARNING An extension cord should not be used with your air conditioner To minimize shock and fire hazards proper grounding is important For your safety and protection this air conditioner is equipped with a special three ...

Страница 6: ...indow sill using Screws Type B The outside edge of window bracket should be center line 6 Place the carpenter s level on the sill and the outdoor end of Sill Bracket Adjust Screw Type A so that Sill Bracket have a slight tilt by using carpenter s level meter about 1 5 WARNING 1 To reduce the risk of electric shock personal injury or death turn the fan control to the OFF position and unplug the uni...

Страница 7: ...the raising of the window from the outside If you have a hard wood or metal window frame a 1 8 inch pilot hole may be needed in order to drive the screw 6 CAUTION 1 The unit is heavy To avoid injury or accident it is strongly recommended that you have additional help when lifting the unit 2 Personal injury or property damage may result if unit falls from window CAUTION Do not drill into window fra...

Страница 8: ...er Step 7 Recheck the Entire Installation CAUTION Do not drill into window sash until window has been inspected to make sure drilling or screw will not damage any locking or lifting mechanism located in the frame CAUTION Do not lift window sash without holding the unit The window sash helps keep the unit in the window Exercise caution when opening the window Failure to do so many result in persona...

Страница 9: ...ERTICAL 3 COOL AIR DISCHARGE 4 GRILLE FRONT 5 PANEL CONTROL 6 AIR INTAKE NO PART NAME 7 AIR FILTER 8 FRAME GUIDE TOP 9 FRAME WINDOW KIT 10 SHUTTER WINDOW 11 REMOTE CONTROLLER NAMES OF MAJOR COMPONENTS 2 3 7 5 1 4 6 8 9 0 2 3 7 5 1 4 6 q ...

Страница 10: ...60 F to 32 C 90 F by 1 C 1 F POWER ON OFF SWITCH To turn the unit ON push this button To turn the unit OFF push this button again MODE SELECT Everytime you push this button It is selected as follow COOLING TURBO FAN COOLING FAN SPEED Everytime you push this button It is selected as follow Low High Low ENERGY SAVE Whenever you push this button the cumulative power consumption is decreased CAUTION W...

Страница 11: ... MODE Everytime you push this button it is selected as follow COOLING TURBO FAN COOLING ENERGY SAVE Whenever you push this button the cumulative power consumption is decreased TEMPERATURE It is the button to set the room in the desired room temp The temp can be set within a range from 16 C 60 F to 32 C 90 F by 1 C 1 F POWER ON OFF To turn the unit ON push this button To turn the unit OFF push this...

Страница 12: ...nd ON OFF TIMER can be selected By remocon button only 1 The desired room temperature is changed within a range from 16 C 60 F to 32 C 90 F by 1 C F 1 FAN SPEED is changed as follows by pushing FAN SPEED button LOW HIGH LOW DISPLAY 1 Current room temperature is displayed 2 COOLING lamp lights 1 Current room temperature is displayed 2 COOLING lamp lights 1 It display desired room temperature when T...

Страница 13: ...by pushing TIMER CANCEL button 1hr 2hr 3hr 4hr 5hr 6hr 8hr 10hr 12hr 16hr 20hr 24hr cancel 2 Unit is off after timer is over 3 If you want to cancel timer push this button again at any time DISPLAY 1 Current room temperature is displayed 2 FAN lamp lights 1 Current room temperature is displayed 2 ENERGY SAVE lamp lights 1 Current room temperature is displayed 2 TURBO lamp lights 1 TIMER lamp light...

Страница 14: ... pushing SLEEP button L1 L2 cancel L1 Mode The unit is off after 4 hours The desired Temp is increased 3 C 5 4 F for 4 hours Fan speed is set to LOW L2 MODE The unit works as follow Fan speed is set to LOW 2 Set proper desired room temperature fan speed 3 This mode can be selected in COOLING mode only DISPLAY 1 TIMER lamp lights 2 Setting time is displayed 3 After a few seconds display is changed ...

Страница 15: ...at the and directions are correct Be sure that both batteries are new Re attach the cover Slide it back into position Do not use rechargeable batteries such batteries differ from standard dry cells in shape dimensions and performance Remove the batteries from the remote controller if the air conditioner is not going to be used for an extended length of time 1 2 3 ...

Страница 16: ...heck in door grill and outdoor louvers for air flow obstructions Do not block air flow to and from unit The outdoor coil should be checked and periodically cleaned for debris that may collect and block unit air flow If air flow is obstructed or deflected back into unit the compressor may cycle on and off rapidly causing early compressor failure GENERAL INFORMATION ...

Страница 17: ...ld detergent solution 5 Cabinet may be washed with mild soap or detergent and lukewarm water then polished with liquid wax for appliances 6 Condenser and Evaporator coils should be cleaned at the beginning of each cooling season Use a soft brush or vacuum cleaner to clean them making sure that the Condenser and Evaporator coils are not damaged 7 Do not use abrasive cleaners These items scrach crac...

Страница 18: ...m the plug Do not use a two prong adapter WARNING Do not remove modify or immerse this plug If this device trips the cause is to be corrected before further use see owners manual This device must only be plugged on appropriate wall outlet Do not use on extension cords USAGE OF POWER CORD AFCI OR LCDI Testing CASE 1 Lamp exists 1 Plug into power receptacle 2 If light is not on press RESET button li...

Страница 19: ... formation on wet surfaces Normal for operation in humid areas Suggested Solution Confirm power cord is plugged in Verify main power switch main circuit breaker or fuse of the unit is good Wait 3 to 4 minutes and restart the unit Clean air filter When blocked by curtains blinds or furnitures etc the air flow is restricted and cooling performance is affected Check with dealer to determine proper un...

Страница 20: ...ed This warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to assume for us any other liability in connection with the sales of our electronic products Over the counter exchange for units that are initially defective Initial defective is described as when the dealer opens the unit and finds that it is inoperative or an individual customer openi...

Отзывы: