background image

  CONTENT

S

P

1

1

Contents.....................................................................................1

Service and Maintenance ..........................................................2

Exploded views and part list .....................................................15

Disassembly and reassembly ....................................................9

Block diagram ..........................................................................21

Controls specification ........................................................ ........4

Troubleshooting ........................................................................13

Wiring diagram .........................................................................20

Содержание DSC-097L

Страница 1: ...Manual de servicio ACONDICIONADOR DE AIRE DSC 097L DSC 127L...

Страница 2: ...CONTENTS P P 1 1 Contents 1 Service and Maintenance 2 Exploded views and part list 15 Disassembly and reassembly 9 Block diagram 21 Controls specification 4 Troubleshooting 13 Wiring diagram 20...

Страница 3: ...d dirt may cause fire FAN OPERATION Take the batteries out of the remote controller Want to use the Air Conditioner Clean filters and replace them to origi nal position Clean indoor unit with soft clo...

Страница 4: ...then push down and close front panel Clean deodorization filters and air cleaner Take out filters first then take out deodorization filter and air cleaner Clean deodorization filter air clean er with...

Страница 5: ...than 8 minutes system will return to normal operation C C AUTO CHANGEOVER MODE Per Room Temperature RT Cooling only type Mode PRE SET Temperature PRE SET Temperature Mode 24 26 RT 2 RT 2 Cool Cool Dry...

Страница 6: ...ESSOR 30S 15S MAX 10 MINS HEAT MODE If Tr Ts heat operation is activated Compressor and outdoor fan are turned on If Tr Ts 1 heat operation is terminated Compressor and outdoor fan are turned off The...

Страница 7: ...Time C CONTROLS SPECIFICATION HIGH PRESSURE PROTECTION If Ti 50 the outdoor fan is turned off After that if Ti 47 the system will start again For 07 09 type C C C C Compressor ON Outdoor Fan OFF Compr...

Страница 8: ...ndoor fan is run at high speed it will change to medium speed If 2 Tr Ts 4 indoor fan keep original speed If Tr Ts 4 indoor fan is run at high speed AUTO FAN SPEED C C C C 0 Tr Ts HIGH SPEED MEDIUM SP...

Страница 9: ...me the switch is pressed it changes in sequence of COOL HEAT STOP MANUAL run operation procedure as the following In the first 30 minutes operation the compressor don t stop indoor fan hold high speed...

Страница 10: ...ion and block the main power 2 Contract the second finger to the left and right handle and pull to open the inlet grille 3 Draw away signal line only for B C D E 6 Put hands at the two ruts of the bod...

Страница 11: ...e out 3 Loosen the screw of the inside terminal board separate the board 6 Pull softly the indoor pipe temperature sensor out from the pipe casing No Parts Procedure Remark 2 Loosen the screw of the i...

Страница 12: ...oks to make the ass y pulled out 4 Evaporator 2 Separete the ass y tray drain from the body 1 Push the left hook and separate the left part out of evaporator 3 Separate the fan motor from the fan No P...

Страница 13: ...the nut flange Turn to the right to remove as it a left turned screw 1 Loosen the fixing screw of the base electrical control 2 Fan motor propeller fan 3 3 Loosen the fixed screw of fan motor separate...

Страница 14: ...t good Air will not immediately blow out at the start of HEAT mode It is processing information air will only blow out when sufficiently warm Please wait This is a way to protect compressor as per mic...

Страница 15: ...ter dropping on the heat exchanger Melting sounds of frost on heat exchanger Indoor unit issue pooosh sound and click sound Click sound of fan or compressor when switc hing ON OFF pooosh sound of refr...

Страница 16: ...Indoor unit Exploded Views and Parts List Model DSC 097L 15 15 Model DSC 127L...

Страница 17: ...e arin g 1 XJ04 01 16 Indoor unit fan 1 KFR 33G 1 4 2 17 Back p anel 1 KF25G 1 1 G1 4 18 M ounting plate 1 KFR 33G 4 14 19 Pip e fix ed clip 1 KFR 33G 1 2 9 21 Electrical control cover 1 KFR 33G 3 1 2...

Страница 18: ...Exploded Views and Parts List Outdoor unit 17 17 Model DSC 097L Model DSC 127L...

Страница 19: ...board supporter 1 KFR20W 3 2 2 12 Left back side board 1 KFR20W 1 2 2 13 Back cover 1 KFR20W 1 2 9 14 Right back side board 1 KFR20W 1 1 3 15 Electrical install board 1 KFR20W 3 2 1 16 Capacitor fixe...

Страница 20: ...0 10 Quantity 1 1 1 1 1 1 1 1 1 1 4 Ass y PCB remocon Screw case up Conduct rubber Inlay LCD LCD screen Spring battery Name Back body Number 11 10 1 2 3 4 5 6 7 8 9 Back cover Conduct rubber 9 9 11 11...

Страница 21: ...SSOR MF MF YLW GRN FAN MOTOR RED YLW BLU YLW GRN MOTOR MC MC BLU N N TERMINAL BED TO INDOOR UNIT WHT 2 2 BLU BLU WHT WHT S S BLU RED CAPACITOR RUN OUTDOOR UNIT WIRING DIAGRAM Wiring diagram 20 20 Mode...

Страница 22: ...y Mode Slector Sleep lamp Timer lamp Temperature lamp Heating lamp cooling lamp Dehumidify lamp wind lamp ON OFF Swing Mode Temperature Set Sleep Mode Timer Fan Speed Operating Mode Receiver Indoor Mo...