35
10.3 Key parts checking.
10.3.1. Compressor checking
(Model: DA89X1C-23EZD1 for MSR1-09HRDN1-QC2(C), DA89X1C-23FZ for MSR1-09HRDN1-QC2(C)).
Measure the resistance value of each winding by using the multi-meter.
10.3.2 Outdoor Fan Motor
(Model: YDK24-6K for MSR1-09HRDN1-QC2(C), YDK24-6G for MSR1-12HRDN1-QC2(C)).
Measure the resistance value of each winding by using the multi-meter.
10.3.3 Indoor Fan Motor (Model:RPG20E).
Measure the resistance value of each winding by using the multi-meter.
10.3.4 Step Motor (Model: MP24GA).
Measure the resistance value of each winding by using the multi-meter.
Position
Resistance Value
Blue - Red
1.10
Ω
(20
Ԩ
)
Blue - Black
Red - Blue
Position
Resistance Value
Black - Red
350
Ω
±8% (20
Ԩ
) for YDK24-6K
435
Ω
±8% (20
Ԩ
) for YDK24-6G
Blue - Red
222
Ω
±8% (20
Ԩ
) for YDK24-6K
213
Ω
±8% (20
Ԩ
) for YDK24-6G
Yellow -
Blue
222
Ω
±8% (20
Ԩ
) for YDK24-6K
213
Ω
±8% (20
Ԩ
) for YDK24-6G
Position
Resistance Value
Black - Red
387
Ω
±8% (20
Ԩ
)
White - Black
378
Ω
±8% (20
Ԩ
)
Position
Resistance Value
Blue - Red
200
Ω
±7% (25
Ԩ
)
Pink - Orange
Pink - Yellow
Yellow - Red
Содержание DSB-F1216LH-DV
Страница 3: ...9 5 Refrigerant cycle diagram ...
Страница 4: ...10 6 Wiring diagram 6 1 Indoor Unit DSB F1216LH DV ...
Страница 5: ...11 6 2 Outdoor Unit DSB F1216LH DV ...
Страница 14: ...DSB F1216LH DV 220 240V 50Hz 1Phase Exploded View Parts for Model ...
Страница 17: ...Exploded View Parts for Model DSB 1216LH DV 220 240V 50Hz 1Phase ...