If the temp. difference condition
②
is satisfied for more than 40 minutes, the defrosting time is 6
minutes.
If the temp. difference condition
①
is satisfied out of 40 minutes, generally the defrosting time is 6
minutes, after three continuous 6-minute defrost, the fourth should be 10 minutes defrost. The
circulation is as following:
→
6-minute defrost
→
6-minute defrost
→
6-minute defrost
→
10-minute defrost
→
8.9.3 Ending
condition of defrosting
If one of following conditions is satisfied, end the defrost and turn into heating mode:
A. The defrost time has reached to 6 or 10 minutes.
B. The compressor current has reached to
I
DEFROST
or above,
I
DEROST
differs in different models.
16
Содержание DMA-2703L
Страница 1: ...Manual de servicio ACONDICIONADOR DE AIRE TIPO MULTI SPLIT Modelo ...
Страница 3: ...3 1 Features 1 1Compact design 1 2High efficiency and quiet operation ...
Страница 5: ...3 Dimensions 3 1 Indoor unit 3 2 Outdoor unit 5 ...
Страница 8: ...6 Wiring diagram 6 1 MS2G 18CR Indoor unit Outdoor unit 8 ...
Страница 9: ...6 2 DMA 2703L Indoor unit 9 ...
Страница 10: ...Outdoor unit 10 ...