37
Change the Main Fuse
(In the left side of
machine compartment)
Start
Power cord or Fuse
is disconnected ?
1’st power of SMPS
is on?
Main PCB Fuse is
disconnected?
Voltage
(DC12V/14.5V/5V) on
Main PCB is OK?
Wire connection
of F-PCB is OK?
Check power Cord connection
from machine compartment and
to CN1 of M-PCB.
Change F-PCB AS.
Change Main PCB
Change the Fuse
(on the Main PCB)
Y
N
N
Y
N
Y
Y
N
Y
N
Checkup and connect
F-PCB wires.
6-1. Faulty Start (F/R lights OFF , F-PCB Power OFF)
6. TROUBLE DIAGNOSIS
1) Insert a flat tip driver into the left down groove of panel frame and snap it out smoothly.
2) Separate 2 housings of 10P / 7P from Front PCB. (Do not hold only wires to pull out.)
3) Unscrew (7 points) to remove Front PCB.
* Follow the reverse order when assembling.
※
How to replace Front PCB (Dispenser Model)
Содержание FRN-U20IC
Страница 4: ......
Страница 5: ......
Страница 6: ......
Страница 7: ......
Страница 33: ...32 5 WIRING DIAGRAM 5 1 FRS U20IC R 134a R C Type...
Страница 34: ...33 5 2 FRN U20IC R 600a R C Type...
Страница 35: ...34 5 3 FRS U20BC R 134a R C Type...
Страница 36: ...35 5 4 FRN U20BC R 600a R C Type...
Страница 37: ...36 5 5 FRS N U20D E F G R 600a or R 134a R C Type...
Страница 68: ...67 8 5 Dispenser Water Flow...