20
1. How to start
1) Press “FRZ.TEMP” button 5 times while pressing
“REF.TEMP” button at the same time.
2. How to stop
1) Push “FRZ.TEMP” button 1 time.
2) It stops automatically in 4 minutes from the start.
3. All the error codes are reset if they turn to be normal.
4. Error display
INPUT
CONTROL OBJECT
CONTENTS
REMARKS
Temperature Control Buttons
Lamp LED of Inner control
(Full down mode and forced defrost mode are displayed while pressing
“REF.TEMP” button at the error display mode)
REF. LED “1” is on and off (twice)
Forced defrost mode for A/S
REF. LED “1” is on
Full Down mode
REF. LED “1” is on and off
EEPROM : defective
REF. LED “2” is on and off
Return after defrosting : defective
REF. LED “3” is on and off
Cycle : defective
REF. LED “5” is on and off
F-Door Switch : defective
FRZ. LED “1” is on and off
R-Door Switch : defective
FRZ. LED “2” is on and off
D-sensor : open (“Lo”), short (“Hi”)
FRZ. LED “3” is on and off
RT-sensor : open (“Lo”), short (“Hi”)
FRZ. LED “4” is on and off
R-sensor : open (“Lo”), short (“Hi”)
FRZ. LED “5” is on and off
F-sensor : open (“Lo”), short (“Hi”)
Display
CONTENTS
4-9. Error Display
4-9-1. FRS(N)-U20IC Type
”1”
LED No
→
”2”
”3”
”4”
”5”
Содержание FRN-U20IC
Страница 4: ......
Страница 5: ......
Страница 6: ......
Страница 7: ......
Страница 33: ...32 5 WIRING DIAGRAM 5 1 FRS U20IC R 134a R C Type...
Страница 34: ...33 5 2 FRN U20IC R 600a R C Type...
Страница 35: ...34 5 3 FRS U20BC R 134a R C Type...
Страница 36: ...35 5 4 FRN U20BC R 600a R C Type...
Страница 37: ...36 5 5 FRS N U20D E F G R 600a or R 134a R C Type...
Страница 68: ...67 8 5 Dispenser Water Flow...