background image

18

The following are additional instructions regarding electrical connections and requirements for electric dryers.

Instructions for Grounding of your Electric Dryer:

a) This dryer must be connected to a grounded metal, permanent wiring system or an equipment-grounding

conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or
lead on the dryer.

b) The dryer has its own terminal block that must be connected to a separate 60 Hertz single phase AC

circuit, fused at 30 Amperes 
(the circuit must be fused on both sides of the line).

ELECTRICAL SERVICE FOR THE DRYER SHOULD BE OF MAXIMUM RATE VOLTAGE LISTED ON
THE NAMEPLATE.
DO NOT CONNECT DRYER TO 110, 115, OR 120 VOLT CIRCUIT.

c) If branch circuit to dryer is fifteen feet (4.50 m) or less in length, use U.L. (Underwriters Laboratories) listed

No. 10 A.W.G. wire (copper wire only), or as required by local codes.
If over fifteen feet (4.50 m), use U.L. (Underwriters Laboratories) listed No. 8 A.W.G. wire (copper wire
only), or as required by local codes.
Allow sufficient slack in wiring so dryer can be moved from its normal location when necessary.

d) The power cord (pigtail) connection between wall receptacle and dryer terminal block IS NOT supplied with

dryer. 
Type of pigtail and gauge of wire must conform to local codes and with instructions mentioned on the
following pages.

e) The method of wiring the dryer is optional and subject to local code requirements. Refer to examples on

next page.

f) You must select the method by which to wire your dryer according to local code and ordinance

requirements.
Sample methods are included in the following pages.

PART 4

ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYERS

Important Warning

To help prevent fire, electric shock, serious injury or death, the wiring and grounding must conform to the latest
edition of the National Electrical Code, ANSI/NFPA 70 and all applicable local regulations.
Please contact a qualified electrician to check your home’s wiring and fuses to ensure that your home has
adequate electrical power to operate the dryer.

120V/ 240V, 60 Hertz, 3-Wire Installation

Содержание DWR-WE3011WW DWR-WE3011RR DWR-WG3011WW DWR-WG3011RR DWR-WE31WW

Страница 1: ...ryer easier ONE TOUCH SELECTIONS To choose an option press its button once No need to press buttons multiple times to scroll through a list of options Your dryer provides sensor drying and time drying...

Страница 2: ...llowed To reduce the risk of fire or explosion electric shock or to prevent property damage personal injury or death when using your appliance follow basic precautions NOTE These manual should be reta...

Страница 3: ...ECIFICATIONS 3 PART 2 INITIAL STEPS FOR INSTALLING YOUR DRYER 7 PART 3 ACCESSORIES INSTALLATION 17 PART 4 ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYER 18 PART 5 ELECTRICAL REQUIREMENTS FOR GAS DRYERS 24...

Страница 4: ...e a load to catch fire 14 Do not use fabric softners or products to eliminate static unless recommended by the manufacturer of the fabric softner or product 15 This dryer is designed only for resident...

Страница 5: ...codes and ordinances Do not modify the plug provided with the appliance If it will not fit the outlet have a proper outlet installed by a qualified electrician B For a permanently connected appliance...

Страница 6: ...asoline away from the dryer Place dryer at least 18 inches above the floor for a garage installation Failure to do so can result in death explosion or fire WARNING To reduce the risk of fire or explos...

Страница 7: ...undry may not tumble properly and sensor will not detect humidity information accurately When leveling please be cautious not to injure your fingers and toes If you install the dryer on the optional p...

Страница 8: ...ith comparable ventilation openings is also acceptable Once in position adjust the leveling legs of the dryer until it is level from left to right and front to back The leveling legs must remain firml...

Страница 9: ...d not rock The maximum slope of the dryer from left to right or front to back should not exceed 1 2 5 cm If the dryer is not level and if the slope exceeds 1 2 5 cm a load may not tumble properly and...

Страница 10: ...few elbow joints as possible Use duct tape on all duct joints Insulate ductwork that runs through unheated areas in order to reduce condensation and lint build up on pipe walls PLEASE BE AWARE THAT FA...

Страница 11: ...le on Gas Dryers 2 2 Reconnect the new duct 8 66 inch 22cm to the blower housing and fixing the duct to the base 3 1 Insert the male end of a 4 elbow into the female end of a short duct Tape the joint...

Страница 12: ...n you remove the shipping cap 3 Connect the dryer to your laundry room s gas supply using a new flexible stainless steel connector as noted below use a new stainless steel flexible connector if allowe...

Страница 13: ...For additional instruction on connecting the dryer to an electrical power source please refer to this manual s section on Electrical Requirements and Electric Dryer NOTE Burner input requirements If y...

Страница 14: ...The adequacy of the airflow can be measured by evaluating the static pressure Static pressure in the exhaust duct can be measured with a manometer placed on the exhaust duct approximately 1 ft 30 5cm...

Страница 15: ...nel Gas dryers must not be vented to the outside using the right side panel because of the burner housing 5 The dryer exhaust duct must be affixed securely to the manufactured or mobile home structure...

Страница 16: ...off 3 Attach the straight end of long hose to Y connector 4 Using pliers tighten the coupling with an additional two thirds turn 5 Attach angled end of long hoses to fill the valve at the bottom of t...

Страница 17: ...om the dryer exhaust outlet B Uninstalling a gas dryer 1 Shut off gas 2 Unplug power cord 3 Disconnect gas line from dryer 4 Pull away and loosen vent clamp 5 Disconnect venting PART 3 ACCESSORIES INS...

Страница 18: ...boratories listed No 8 A W G wire copper wire only or as required by local codes Allow sufficient slack in wiring so dryer can be moved from its normal location when necessary d The power cord pigtail...

Страница 19: ...e instructions in this section if your home has a 3 wire receptacle NEMA type 10 30R and you will be using a UL listed 120 240 volt minimum 30 amp dryer power supply cord 4 wire receptacle NEMA type14...

Страница 20: ...k 1 inch 2 5 cm Make ends of 3 wires a hook shape Then put the hooked shape end of the wire under the screw of the terminal block hooked end facing to the right and pinch the hook together and screw t...

Страница 21: ...from end and strip 1 inch of insulation from each conductor 3 wire connection Direct wire Then put the hooked shape end of the wire under the screw of the terminal block hooked end facing rightward an...

Страница 22: ...nal block screw 2 Connect red and black wires to the left and right terminal block screws 3 Connect ground wire green of power cord to external ground screw and move neutral ground wire of appliance a...

Страница 23: ...e connection of a frame grounding conductor to the neutral wire use the instructions under this section 1 Connect neutral wire white of power cord to center terminal block screw 2 Connect ground wire...

Страница 24: ...same circuit a The dryer has a three prong plug to help guard against shock The plug should be plugged directed into a properly grounded three prong receptacle that is rated 120 Volts AC alternating c...

Страница 25: ...er to the type of gas shown on the nameplate Use new flexible stainless steel connectors Use Teflon tape and pipe joint compound insoluble in LP gas on all pipe threads Purge gas supply of air and sed...

Страница 26: ...ryer 3 Rigid or semi rigid metal ducting is recommended for use as transition ducting between the dryer and and the wall In special installations when it is impossible to make a connection with the ab...

Страница 27: ...nnection when servicing the dryer because wiring errors can cause serious injury to you and your dryer Cleaning the Lint Screen 1 Clean the lint filter once either before or after drying each load Alw...

Страница 28: ...ctions can result in death explosion or fire Following are instructions for starting and using your new dryer Please refer to specific sections of this manual for more detailed information Important W...

Страница 29: ...cterial or Damp Dry Beep is not available Level More Time Less Time Custom Rack Dry Wrinkle Anti Damp Dry Program Care Bacterial Beep Bulky Large O O O O O Heavy Duty O O O O O Cotton Towls O O O O O...

Страница 30: ...iron finishes Ultra Delicate Use for drying gentle items such as workout wear shear and lace items 2 Manual Dry Cycles Use Manual Cycles to select a specific amount of drying time and a drying tempera...

Страница 31: ...hild Lock When Wrinkle Care is selected the light for Wrinkle Care will glow in the display When power is on CHECK FILTER is displayed until start pause is selected 4 Status Clean Filter Wrinkle Care...

Страница 32: ...er filling Stuffed toys foam rubber filled Foam rubber pillows Athletic shoes NOTE Do not use this cycle with delicate fabrics NOTE DRY LEVEL selections can only be made while using Sensor Dry Cycles...

Страница 33: ...rols the volume of the beep that is made when you press any of the buttons on the control panel Press BEEPER to adjust the sound level or turn off the signal Beeper 11 Use this button for start or pau...

Страница 34: ...tomatically shut off If you wish to end your drying cycle after pressing START PAUSE press START PAUSE again To stop your dryer at any time Press START PAUSE or open the door NOTE The MORE TIME or LES...

Страница 35: ...My Dryer Displayed An Error Code Question Is the fuse blown or is the circuit breaker tripped Is the gas supply or service blocked or off What to Do If the fuse is blown or the circuit breaker trippe...

Страница 36: ...clothing are empty before washing and drying 5 Problem There Is Lint On My Clothes Question Did you use fabric softener Did you over dry the load of laundry Are you drying synthetic permanent press an...

Страница 37: ...ing freely that the dampers are not pushed in and that nothing has been set against the dampers Check your home s or laundry room s fuse box circuit breaker box and replace the fuse or reset the circu...

Отзывы: