3) H5 Error - Water temperature error in wool/ delicate course
 

 In case water temperature in wool/ delicate course is 45

 or higher

 

 Error buzzer alarm is sounded for 10 seconds per every 10 minutes.

 

 Error display is cleared when turning off/ on power. 

4) H6 Error - Abnormality in washing heater
 

  Within 15 minutes after heater operation begins;  

 

 

 

 

 

In case standard temperature is of 42

 or lower: If temperature does not increase by 2

 or more In 

case standard temperature is higher than 42

: If temperature does not increase by1

 or more

 

  If temperature falls below standard temperature by 2

 or more due to re-supply of water, etc., 

standard temperature is reset as the current temperature and error check time of15 minutes is reset. 

 

 Error buzzer alarm is sounded for 10 seconds per every 10 minutes. 

 

 Error display is cleared when turning off/ on power. 

5) H8 Error - Washing heater overheating
 

  In case washing heater temperature increases by 5

 or more within 30 seconds when there is no 

water in tank, etc. 

 

 Error buzzer alarm is sounded for 10 seconds per every 10 minutes. 

 

 Error display is cleared when turning off/ on power. 

Содержание DWD-L1212

Страница 1: ...2009 Caution In this Manual some parts can be changed for improving their performance without notice in the parts list So if you need the latest parts information please refer to PPL Parts Price List...

Страница 2: ...12 Dimension mm 600 X 645 X 850 Maximum mass of textile kg 9 Kg Unit Weight net gross 78 82 71 75 Standard Water Consumption 65 Spin Speed RPM DWC DWD LU10XX MAX 1000 DWC DWD LU12XX MAX 1200 DWC DWD L...

Страница 3: ...4 1 PANEL AS 3 Partslistbyass y A03 A02 A22 A21 A19 A20 A15 A14 A11 A09 A16 A18 A17 A01 A04 A05 A06 A07 A08 A10 A12 A13 1st Model...

Страница 4: ...TOM LED 3613058300 C LU1011 1 A11 LED LAMP DS0302WP 9MM FORMING TYPE D 3MM 36 A12 SW TACT 5S50101402 2PIN 6 6 5 9 A13 HOLDER LED OPTION 3613058000 HIPS 1 A14 HOLDER LED FUNCTION 3613058100 HIPS 1 A15...

Страница 5: ...8 B01 B02 B03 B05 B04 B08 B07 B06 B10 B09 B11 B12 B13 B14 3 INLET BOX AS...

Страница 6: ...0 EPDM ID9 5 OD14 5 WASHING 1 B08 HOSE WATER SUPPLY 3613268900 EPDM ID9 5 OD14 5 PRE WASH 2 B09 CLAMP HOSE 3611205800 100H ID 13 8 W 10 0 0 9T 10 B10 VALVE INLET 3615414820 220 240V 1 WAY HOT PP 1 B11...

Страница 7: ...10 4 CABINET F ASSY C12 C01 C02 C03 C14 C15 C06 C07 C04 C05 C11 C08 C09 C10 C13 1st Model...

Страница 8: ...BS 1 C05 PROTECTOR GLASS 3618345500 ABS 1 C06 DECORATOR DOOR O 3611695900 ABS 1 C07 HOOK DOOR 3613100900 ZNDC 1 C08 SPRING HOOK 3615115400 SUS304 1 C09 HOOK SHAFT 3613101000 SUS D 3 0 1 C10 FRAME DOOR...

Страница 9: ...Y UNIVERSAL D26 D23 D22 D25 D24 D20 D18 D17 D19 D16 D15 D10 D21 D11 D04 D07 D05 D06 D08 D03 D01 D02 D43 D32 D46 D38 D45 D50 D47 D48 D49 D36 D35 D37 D40 D28 D30 D27 D29 D31 D34 D09 D13 D14 D12 D44 D42...

Страница 10: ...BEARING INNER 3616303100 6206Z 1 D31 UNIT MOTOR UNIVERSAL36189L4H00 DC220 50 G J 2P PI340 45T CCA 1 D32 BALANCER WEIGHT LOWER 3616110300 PP D LU1011 3 5KG 1 D33 SPECIAL SCREW 3616029400 SWCH 8 5X30 2...

Страница 11: ...20 9 CABINET AS F07 F01 F03 F02 F04 F05 F10 F09 F08 F06 F11 F12 F13...

Страница 12: ...MAIN PCB AS 3610PCBL55 C LD1213LHS02 1 MAIN PCB AS 3610PCBL50 C LD1412EFA02 1 MAIN PCB AS 3610PCBL00 D LU1212EFA 1 MAIN PCB AS 3610PCBL51 C LD1212MFA 1 F07 PLATE T 3614541110 SECC 1 2T C LU1011 1 F08...

Страница 13: ...k S W Open 2 More details When turn on LOCK signal all process is conducting normaly When working starts the PCB displays all the sensor conditions In this case BLDC Motor is not tested In order to te...

Страница 14: ...ned off and OE blinks in 18 88 display 3 Error buzzer alarm is sounded for 10 seconds per every 10 minutes 4 Error display is cleared when turning off on power 6 3 UE Unbalance Error 1 Conditions of O...

Страница 15: ...line test mode 2 Water supply motor is kept on until water level falls below reset 3 All LEDs are turned off and E1 blinks in 18 88 display 4 Error buzzer alarm is sounded for 10 seconds per every 10...

Страница 16: ...for 10 seconds per every 10 minutes 4 Error display is cleared when turning off on power 6 8 E9 Abnormalities in water level sensor 1 Conditions of Occurrence In case water level frequency is of 15KH...

Страница 17: ...window Error buzzer alarm is sounded for 10 seconds per every 10 minutes Error display is cleared when turning off on power 4 E8 Initial Operation Fail Error In case input signal of Hall IC is abnorma...

Страница 18: ...emperature is higher than 42 If temperature does not increase by1 or more If temperature falls below standard temperature by 2 or more due to re supply of water etc standard temperature is reset as th...

Страница 19: ...41 DWD LU S...

Отзывы: