31
31
5-1. Testing Mode
PCB and other electronic parts will be tested without water supply whether they are normal or not.
1) Process
Press power button
→
Press "SPIN" button 3 times with pressing "OPTION" button
→
'L d' will be
shown on LED
→
Whenever pressing "TEMP" button 1 time, below process will be occurred.
MICOM Ver.
→
L C (Lock Closed)
→
Run (count)
→
b1, b2, b3, b4, b5, b6,
→
F (Fan Motor)
→
H (Hot V/V)
→
C (Cold V/V)
→
P (prewashing V/V)
→
d ( dry V/V)
→
s(steam V/V)
→
bb (bubble)
→
dr (drain motor)
→
CR(circulation)
→
L O(Lock S/W Open)
2) More details
①
When turn on 'LOCK' signal, all process is conducting normaly.
②
When working starts, the PCB displays all the sensor conditions.
③
In this case, BLDC Motor is not tested. In order to test it, select spin or rinse.
5-2. Continous testing mode
1) Process
After pressing "TEMP", "OPTION", "SPIN" button simultaniously, press "POWER" button.
ALL LED On
→
SPIN button
→
ALL LED off
→
L C (Lock Close)
→
r (Motor right)
→
L (Motor Left)
→
F ( Fan Motor)
→
H (Hot V/V)
→
C (Cold V/V)
→
b (Pre whsh V/V)
→
d ( dry V/V)
→
bb (bubble)
→
h1 (Wash heater)
→
h2(Dry heater)
→
dr (Drain motor On)
→
L O(Lock S/W Open)
2) More tails
①
LED test can be done with all LED On.
②
All sensor conditions will be shown on PCB during processing.
5. TEST MoDE