2-1. SERVO CIRCUIT ADJUSTMENT METHOD
1. PLAYBACK PHASE
• Connection Method
• Adjustment Procedure
1) Play back the test tape.(DP-2)
2) Set the oscilloscope to the CHOP mode. Connect CH1 to the SW PULSE (PT01 PIN
¤Ø
).
3) Insert PATH JIG and Press “REC” button on the remote controller.
4) Check the position of the V-sync from the rising edge of the SW pulse.
(Standard: 6.5H±0.5H)
SECTION 2.
ELECTRICAL ADJUSTMENT
Adjustment Parts
Checking Point
Measuring Equipment
Mode
Test Tape
JPT01
DP-2
Check
PT01 PIN
¤Ø
Oscilloscope
Play
Modulator
JPT01
CH-1
OSCILLOSCOPE
CH-2
PT01
TOP VIEW
PATH JIG