Low Pressure

1.  

Should pressure drop from extended use

 

  or other factors:

 

  OUTPUT connections 2,4 will be OPEN

 

  RED LED = “NG” pressure.

2.  

System may need nitrogen charging, if low

 

  service and refill.

3.  

GREEN LED = “GOOD” pressure.

4.

  Production operations may resume.

Troubleshooting

   Do not open Control Panel. Components are not designed for user 

service or modification.

No Power

 

 Check wire connections

 

– 

Check cable plug tightness

 

– 

Replace cable

OUTPUT closed/ GREEN LED on - when it should be open/RED

 

– 

Panel charged but not connected to system

 

– 

Internal problem call DADCO for service

OUTPUT open/ RED LED on -  when it should be closed/GREEN

 

– 

Check connections

 

– 

Check plug tightness

Nitrogen Leaks

 

– 

Check fittings, gauge and rupture disc for leaks.

 

– 

Replace seals or components as required.

SENSOR not responding to button inputs

 

– 

Check to see if the unit has been LOCKED (see above).

 

– 

Disconnect power and repower SENSOR.

低圧時

1.  

拡張使用時または他の要因で圧力が低下した場 

      合、出力接点

2,4

は開になります。

      赤色

LED

により、圧力

 “NG” 

を示します。

2.  

窒素充填、修理、補充の必要が考えられます。

3.  

緑色

LED

により、圧力 

“GOOD” 

を示します。

4.

 

 生産開始が可能になります。

トラブルシューティング

    コントロールパネルは開けないで下さい。この装置はお客様による修理・保全用 

は設計していません。

電源が入らない

– 

配線接続を確認して下さい。

– 

電線プラグがしっかり接続されているか確認して下さい。

– 

電線を交換してください。

出力 開/赤色

LED

点灯であるべきところ、出力 閉/緑色

LED

点灯となった場合

– 

パネルには電源が来ているがシステムには接続されていないか確認して

    さい。

– 

内部故障はダドコサービスに連絡して下さい。

出力 閉/緑色

LED

点灯であるべきところ、出力 開/赤色

LED

点灯となった場合

– 

配線接続を確認して下さい。

– 

電線プラグがしっかり接続されているか確認して下さい。

窒素ガス漏れ

– 

配管コネクタ、計器、破裂板式安全装置からの漏れがあるか確認下さい。

– 

必要に応じてシールや装置を交換下さい。

センサーのボタン入力が無効

– 

装置がロックされているかどうか確認して下さい。(上記参照)

– 

センサーの電源を入れ直してください。

設定

生産

1.  

コントロールパネルへ適切な電線を接続して下さい。

 

  

出力接点

2,4

は電源オフ時で開です。

2.  

電源投入により、センサーは現在圧力を表示します。 

   窒素ガスを充填しシステムを生産圧力にして下さい。

 

  

出力

S1

はオンになります。

      出力接点

2,4

は閉になります。

     

緑色

LED

により、圧力

 “GOOD” 

を示します。

3. 

 

生産開始が可能になります。

4.

  

センサーが偶発によりロックになった場合、モード 

     ボタンと上向き矢印ボタンを一緒に3秒間押します。

   “ Lok “ 

が少しの間表示されと圧力モニタリングが再 

      開されます。

5.

  

センサーがロックからアンロックになった場合、モ 

       ードボタンと上向き矢印ボタンを一緒に3秒間押し 

       ます。

   “ UnL “ 

が少しの間表示されと圧力モニタリングが再 

      開されます。

1.  

コントロールパネルへ適切なケーブルを接続して下さい。 ケーブルは、必要に 

  じて生産システムに配線して下さい。

2.  

ケーブルワイヤー1,3はセンサー読出を起動させる能力が必要です。

3.  

数秒後、圧力モニターは現在の圧力値を表示します。

4.  

出力レベルを設定するため、モードボタンを押してください。

A-1

が表示さ 

  れす。

 

  A-1 

の設定レベルを調節するため、矢印ボタンにて圧力増減して下さい。 

  

A-1 

の標準設定値は 

8.0 MPa

です。一旦 

8.0 MPa

以下になると、出力

S1

はオフ 

  になります。

5.  

最大値レベルを設定するため、モードボタンを押してください。

b-1 

が表示さ 

  れます。

 

  b-1 

の設定レベルを調節するため、矢印ボタンにて圧力増減して下さい。

 

  b-1 

の標準設定値は 

40.0 MPa

です。このセッティングは、最大圧力より高く設 

  定されます。

6.  

設定完了するため、モードボタンを3秒間押してください。センサーは圧力モ 

  ニタリングに戻ります。

®

Nitrogen Gas Spring  

Accessories

1.734.207.1100 • fax 1.734.207.2222 • www.dadco.net

1.  

Connect proper cable to control panel.  Cable should be wired into the

 

  production system as required.

2.  

Cable wires 1,3 must have power to activate the SENSOR READOUT.

3.  

After a few seconds the PRESSURE MONITORING will turn on and 

 

  display current pressure. 

4.  

To setup the OUTPUT LEVEL press the Mode button for one second until

 

  A-1 is shown. To adjust the setting level of A-1 use the arrow buttons to

 

  increase or decrease pressure.

 

  A typical setting for A-1 would be 8.0 MPa. Once pressure falls below 8.0

 

  Mpa, output S1 will turn off.

5.  

To setup the MAXIMUM LEVEL press the Mode button for one second until

 

  b-1 is shown. To increase the setting level of b-1 use the arrow buttons to

 

  increase or decrease.

 

  A typical setting for b-1 would be 40.0 MPa. This setting is set higher than

 

  maximum pressure.

6.  

To complete setup press MODE for 3 seconds. The sensor will return to

 

  PRESSURE MONITORING.

2

Setup

Production

1.  

Connect proper cable to control panel.

 

  

OUTPUT connections 2,4 will be OPEN without power.

2.  

On power up the SENSOR will display current pressure.

 

  Charge Nitrogen system to production pressure. 

 

  OUTPUT S1 will indicate ON.

 

  OUTPUT connections 2,4 will be CLOSED.

 

  GREEN LED will show “GOOD” pressure.

3.  

Production operations can commence.

4.

  To LOCK sensor from accidental change,

 

  press MODE + UP ARROW together for 3

 

  seconds.

 

  Lok will display momentarily and

 

  PRESSURE MONITORING will resume.

5.

  To UNLOCK sensor from LOCK state,

 

  press MODE + UP ARROW together for 3

 

  seconds.

 

  UnL will display momentarily and

 

  PRESSURE MONITORING will resume.

Operation

Operate SENSOR from front 
panel.
Do not open Control Panel. Panel 
is not designed for user service or 
modification.

操作手順

パネル前面からセンサーを操作し

て下さい。
コントロールパネルは開けないで下

さい。お客様による修理・保全用に

は設計していません。

Содержание 90.406.421

Страница 1: ...s output S2 contact DADCO for detailed instructions このコントロールパネルは 窒素充填ガススプリングシステムの圧力表示 調節に使 用します 独自のスイッチング出力で 設定圧以下になるとプレス生産工程を止める ことが出来ます モニタリングとスイッチング機能を有するため パネルには電源供 給が必要です 媒体 窒素ガス 圧力 最大充填圧 20 C 定格圧力 15 MPa 35 MPa センサー標準 150 bar 350 bar 2175 psi 5075 psi 拡張設定 このコントロールパネルは センサ ーメニューの一部の限定範囲で動 作するように設計されています 出力S2は出力プラグには出力伝送 しません 他の設定および修正は 推奨しません 交流装置 出力設 定 ヒステリシス 出力S2の使い方 についての操作詳細は ダドコにお 問い合わせ...

Страница 2: ...るため モードボタンを押してください A 1が表示さ れす A 1 の設定レベルを調節するため 矢印ボタンにて圧力増減して下さい A 1 の標準設定値は 8 0 MPaです 一旦 8 0 MPa以下になると 出力S1はオフ になります 5 最大値レベルを設定するため モードボタンを押してください b 1 が表示さ れます b 1 の設定レベルを調節するため 矢印ボタンにて圧力増減して下さい b 1 の標準設定値は 40 0 MPaです このセッティングは 最大圧力より高く設 定されます 6 設定完了するため モードボタンを3秒間押してください センサーは圧力モ ニタリングに戻ります Nitrogen Gas Spring Accessories 1 734 207 1100 fax 1 734 207 2222 www dadco net 1 Connect proper cable to...