3
Cabinet Preparation
The cutout depth should be 24
″
The cutout dimensions shown allow for a full door swing and access to the pull-out racks when
installed as a built-in in standard 24
″
deep cabinets.
•
The wine chiller, wine reserve and beverage center can be installed freestanding.
• If installing between frameless cabinets, a 1/2
″
wide filler strip or side panel may be
needed on hinge side. The filler strip will act as a spacer between the case and adjacent
cabinet door swing.The width of the opening must include the filler panels.
NOTE:
The front face of the chassis should be even with the adjacent cabinetry.
SIDE-BY-SIDE INSTALLATIONS
Increase storage capacity by installing two beverage centers or wine chillers together.
•
A side-by-side installation requires at least a 47-1/2″ wide opening. No trim kits required.
• Products must operate from separate, properly grounded receptacles.
STACKED INSTALLATIONS
Increase storage capacity by installing two beverage centers or wine chillers together.
• A stacked installation requires at least a 23 3/4” wide opening. No trim kits required.
• A cutout height of 34 1/2” - 35” is required.
• A minimum of 2” rail is required between units.
• A 3/4” or better support platform must be provided for the upper unit.
• Products must operate from separate, properly grounded, receptacles.
Electrical Power Supply
Requirements
NOTES:
1. If the power supply
requirements shown do
not agree with those listed
on the product data plate,
provide a power source per
the information found on the
product data plate.
2. If the electrical service
provided does not meet the
product specification, or
does not conform to the NEC
or local standards, do not
proceed with the installation.
Call a licensed electrician to
correct the electrical service
before proceeding.
3. Be certain to locate the
electrical receptacle in an
accessible location, so that
the appliance may be easily
unplugged in the event that
service becomes necessary.
4. Do not use an extension cord
to connect the appliance to the
electrical receptacle.
5. It is the owner’s responsibility
to ensure that electrical
installation of this appliance is
performed by a qualified
electrician. The electrical
installation must comply
with the National Electric
Code ANSI/NFPA 70-1990 (or
to latest revision) and local
codes and ordinances.
6. GFI (ground fault interrupter)
is not recommended
Electrical Supply Requirements
120VAC, 60 Hz, 15A Dedicated Circuit
Appliance is supplied with a 48” (1219mm)
power cord with a three prong grounded
plug.
Total Connected Load
.01kW (1.2A)
Locate
Outlet
10 1/2”
(267mm)
9“ Max.
(229mm)
24”
(610mm)
34 1/2” - 35”
(876mm - 889mm)
1 1/2”
(38mm)
23 3/4” Min.
(603mm)
Locate Outlet
24”
(610mm)
1 1/2”
(38mm)
47 1/2” Min.
(1207mm)
15”
(381mm)
10 1/2”
(267mm)
10 1/2”
(267mm)
9“
(227mm)
34 1/2” - 35”
(876mm - 889mm)
Содержание Wine Steward/Beverage Cooler