background image

3

Product Specifications

Electrical Requirements

• 

It is the owner’s responsibility to ensure that a licensed 

electrician performs the installation of the electrical supply for 

this appliance. The electrical installation, including minimum 

supply wire size, must comply with the National Electric 

Code ANSI/NFPA 70 (latest revision) and local codes and 

ordinances.

A copy of this standard may be obtained from:

 

National Fire Protection Association 

1 Batterymarch Park 

Quincy, Massachusetts 02269-9101

• 

The correct voltage, frequency and amperage must be 

supplied to the appliance from a dedicated, grounded, single 

phase circuit that is protected by a properly sized circuit 

breaker or time-delay fuse. If a time-delay fuse is utilized, 

fuse both sides of the line (L1 and L2).

35”

(88.9 cm)

5/16”

(8 mm)

11/16” - 1 13/16”

(1.7 cm - 4.6 cm)

Removable (factory installed)

3” (7.6 cm) side panels

Optional full size side panels

(ARSL30S, ARSR30S)

56” (142 cm) long

240 Vac 4 wire

conduit location

Door opened

Range top

23 1/2”

(59.7 cm)

25 5/16”

(64.3 cm)

Rear of control

Panel/oven door

Max. depth

to front of

control panel

with door closed

29 15/16”

(76.0 cm)

45 5/16”

(115.1 cm)

Product tolerances: ±1/16” (±1.6 mm), unless otherwise stated

Product Dimensions

Dimensions - Top View

Dimensions - Isometric View

 WARNING

If the electric service provided does not meet the product 

specifications, do not proceed with the installation. Call the 

selling dealer or a licensed electrician.

Electrical Specifications

Dedicated Circuit 

Requirements

Total Connected Load

240 Vac 60 Hz, 

4 wire*, 50 Amp.

10.3kW (48.2 Amp.)

* Two 120 Vac hot (L1 and L2), one neutral (N1) and one ground.
The above electrical specifications are for reference only. See 

the range data plate for exact specifications. See inside cover for 

location.

NOTE:

 If the appliance is connected to a 208 volt power supply, 

preheat times and cavity temperature recovery times will be 

increased slightly.

Содержание Renaissance Series MRES30S

Страница 1: ...Installation Instructions Renaissance Electric Range Part No 65166 Rev N Model MRES30S ...

Страница 2: ... 6 Removing the Oven Door 8 Remove the Kick Panel 8 Electrical Connection 8 Installing the Range 10 Re installing the Oven Door and Kick Panel 10 Verifying Proper Operation 10 Customer Service Information If You Need Help If you have questions or problems with installation contact your Dacor dealer or the Dacor Customer Service Team For repairs to Dacor appliances under warranty call the Dacor Dis...

Страница 3: ...sages in the oven bottom or cover an entire rack with materials such as aluminum foil Doing so blocks air flow through the oven and may cause a fire hazard Aluminum foil linings may also trap heat causing a fire hazard WARNING Tip over hazard A child or adult can tip the range and be killed Attach the anti tip bracket to the floor or wall as directed in these installation instructions Engage the f...

Страница 4: ...th surface countertop ventilation systems The use of an overhead hood or Dacor raised vent is recommended for ventilation Disconnect the electrical supply before installing or servicing the appliance Install or locate this appliance only in accordance with these installation instructions This appliance must be grounded Connect only to a properly grounded electrical supply Refer to Electrical Requi...

Страница 5: ...d 3 7 6 cm side panels Optional full size side panels ARSL30S ARSR30S 56 142 cm long 240 Vac 4 wire conduit location Door opened Range top 23 1 2 59 7 cm 25 5 16 64 3 cm Rear of control Panel oven door Max depth to front of control panel with door closed 29 15 16 76 0 cm 45 5 16 115 1 cm Product tolerances 1 16 1 6 mm unless otherwise stated Product Dimensions Dimensions Top View Dimensions Isomet...

Страница 6: ...urface units should be avoided If cabinet storage space is to be provided directly above the range the risk of personal injury may be reduced by installing a ventilating hood that projects horizontally a minimum of 5 inches 12 7 cm beyond the face of the cabinets The range may be installed flush to the rear wall Dacor recommends installing a noncombustible material on the rear wall above the range...

Страница 7: ... the range both sides Top View Downdraft ERV30 15 with Slide In Self Rimming Installation using 3 Side Panels with Backguard Removed Top View Slide In Self Rimming Installation using 3 Side Panels with Backguard Removed 29 1 4 74 3 cm 13 32 1 0 cm 30 1 16 76 4 cm 27 5 8 70 2 cm Backsplash 3 8 1 0 cm Min flat ledge Vertical non combustible rear wall surface 2 9 16 6 5 cm Notches for mounting raised...

Страница 8: ...ttaching the bracket to a concrete sub floor Do not use the anchors when attaching to a wood sub floor 1 Determine the location of the range center line and front panel for the range s final position based on the Product Dimensions on page 3 and the actual cabinet cutout dimensions used for the installation 2 Determine the required position of the anti tip bracket based on the diagram below Mark t...

Страница 9: ...ase plate inside the wall and that any floor covering is not too thick for proper screw thread engagement To determine if the base plate is high enough a Determine the location of the range center line and front panel when the range is in its final position based on the product dimensions on page 3 and the actual cabinet cutout dimensions used for the installation b Determine and mark the required...

Страница 10: ... appliance Such use may result in fire electrical shock or other personal injury Do not install a fuse in the neutral or ground circuit A fuse in the neutral or ground circuit may result in an electrical shock hazard Do not ground the appliance to a gas supply pipe or hot water pipe A grounded cold water pipe must have metal continuity to electrical ground and must not be interrupted by insulating...

Страница 11: ...ut of the appliance conduit 2 Connect the white appliance wire to the neutral white supply wire in the junction box 3 Connect the black appliance wire to the black L1 power supply wire in the junction box 4 Connect the red appliance wire to the red L2 power supply wire in the junction box 5 Connect the green appliance wire to a grounded supply wire in the junction box or to a grounded cold water p...

Страница 12: ...ing use and care manual carefully Important safety service and warranty information are contained within When the unit is powered on for the first time the cooktop control will go through a self check routine When the self check is complete the cooktop control will go into secure mode See the use and care manual for secure mode instructions 1 Turn on the power supply to the range 2 Set the time of...

Страница 13: ...11 Notes ...

Страница 14: ...12 Notes ...

Страница 15: ......

Страница 16: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com ...

Отзывы: