background image

Dacor  

  14425 Clark Avenue, City of Industry, CA 91745  

  Phone: (800) 793-0093  

  Fax: (626) 403-3130  

  www.dacor.com

Содержание Renaissance RR30NFS

Страница 1: ...Installation Instructions Renaissance Electric Range Part No 105910 Rev A Models RR30NS RR30NS C RR30NFS RR30NFS C RR30NIS and RR30NIFS with induction cooktop...

Страница 2: ...al number are printed on the product data label Dacor Customer Service Phone 800 793 0093 extension 2813 U S A and Canada Monday Friday 6 00 a m to 5 00 p m Pacific Time Web site www dacor com Dacor D...

Страница 3: ...eath warning NEVER use this appliance as a space heater to heat or warm the room Doing so may result in overheating of the appliance warning NEVER cover any slots holes or passages in the oven bottom...

Страница 4: ...iance is not approved for installation in a mobile home or recreational vehicle This appliance must not be used in combination with surface countertop ventilation systems The use of an overhead hood o...

Страница 5: ...ion box or A 3 wire conduit where local code permits connected to a 3 wire junction box Suggested conduit wiring color code black white red and green Using an appliance cord A 4 wire appliance cord eq...

Страница 6: ...piece in place of a backguard A backguard may be purchased as an optional accessory Add an additional 1 16 inch to the depth dimensions above when installing a backguard on models RR30NIS and RR30NIF...

Страница 7: ...ications for minimum clearances If cabinet storage space is to be provided directly above the range the risk of personal injury may be reduced by installing a range hood The range may be installed flu...

Страница 8: ...tion Models RR30NIS and RR30NIFS Only To create a built in look on the front of the cabinet this dimension may be changed to 29 1 4 74 3 cm with the width at the notches remaining 30 1 16 This configu...

Страница 9: ...this dimension may be changed to 29 1 4 74 3 cm with the width at the notches remaining 30 1 16 This configuration is only for models RR30NIS and RR30NIFS with the side panels behind the door removed...

Страница 10: ...quired The minimum full thread depth portion of screw threaded into wood slab for wood is 3 8 1 cm and 5 8 1 6 cm for concrete See the table below to select the correct screw size Sub Floor Type Floor...

Страница 11: ...thod may not be used and the floor mounting method must be suitable or the wall must be modified so that the base plate is above the notches 4 To install the bracket place it against the wall in the m...

Страница 12: ...ng can cause an electric shock hazard and damage the appliance Dacor is not responsible for damages resulting from improper installation This range must be connected to a grounded metallic permanent w...

Страница 13: ...relief inside the box Tighten into place 6 Connect the white wire to the neutral terminal inside the box 7 Connect the black wire to the L1 power supply terminal 8 Connect the red wire to the L2 powe...

Страница 14: ...ce inside the junction box 2 Connect the white wire from the appliance to the neutral white supply wire inside the junction box 3 Connect the black wire from the appliance to the black L1 power supply...

Страница 15: ...Conduit Junction Box Connection with External Ground Separate No 10 minimum copper grounding wire Wire nut 4 places Conduit to appliance Conduit to appliance Wire nut 3 places Junction box Junction b...

Страница 16: ...onnection cont Appliance Cord Connections Where Local Code Permits warning Do not connect the green appliance wire to the neutral white supply wire unless local building codes permit 1 Remove the rang...

Страница 17: ...umper link Link removed Ground screw L2 terminal L2 terminal L1 wire L1 wire White wire White wire Green wire L2 wire L2 wire Strain relief Strain relief 3 Wire Appliance Cord Connection Where Local C...

Страница 18: ...loor to the countertop and adjust the leveling legs as required to position the top frame at the desired height based on the cabinet and countertop installation 2 Carefully slide the range into positi...

Страница 19: ...e troubleshooting steps Verify that power is being supplied to the range Check the electrical connections to ensure that the installation has been completed correctly Repeat the above tests If the app...

Страница 20: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Отзывы: