background image

8

Installation Instructions

Verify the Package Contents

Verify that all the components below have been provided. If 

any item is missing or damaged, please contact your dealer 

immediately. Do not install a damaged or incomplete appliance. 

Make sure that you have everything necessary to ensure proper 

installation before proceeding.

• 

Use and care manual

• 

Anti-tip bracket with screws and anchors

• 

Oven racks (2)

• 

Razor blade scraper

• 

Dacor Cooktop Cleaning Cream

Installing the Anti-Tip Bracket

Locate the anti-tip bracket included in the parts box.

There are two ways to mount the anti-tip bracket:

• 

Floor mounting (preferred method).

• 

Wall mounting (alternate method). Use this method if floor 

mounting is not suitable. If any of the conditions below exist, 

then the wall mounting method can not be used and the floor 

mounting method must be suitable.

The anti-tip bracket may not be mounted to the wall if:

◊ 

The wall contains metal stud mounting materials that 

interfere with the anti-tip bracket mounting screws.

◊ 

The front panel of the range is further than the maximum 

distance from the back wall stated on page 9.

◊ 

A raised vent is installed.

◊ 

The flooring is too thick (see 

Installing the Anti-Tip 

Bracket on the Wall

).

Installing the Anti-Tip Bracket on the Floor

 

wARNINg

To perform its intended function, the anti-tip bracket must be 

attached as instructed to the concrete slab or wood sub-floor 

below any floor coverings (including cement board) on top. Do 

not attach the anti-tip bracket directly to floor coverings such as 

ceramic/asphalt tile or linoleum.

Four (4) plastic anchors are provided along with three sizes  

(4 each) of #8 or #12 Phillips head screws for attaching the anti-

tip bracket to the floor. Use both the anchors and four (4) of the 

#8 screws when attaching the bracket to a concrete sub-floor. Do 

not use the anchors when attaching to a wood sub-floor.

1.  Determine the location of the range center line and front 

panel when the range is in its final position based on the 

Product Dimensions

 on page 4, and the actual cabinet/ 

cutout dimensions used for the installation.

2.  Determine the required position of the anti-tip bracket, 

based on the diagram on the facing page. Mark the four (4) 

mounting hole locations on the floor with a pencil.

3.  Determine the screw size required. The minimum full thread 

depth (portion of screw threaded into wood/slab) for wood 

is 3/8” (1 cm) and 5/8” (1.6 cm) for concrete. See the table 

below to select the correct screw size.

Sub-Floor Type/ 

Floor Covering Thickness

Screw Size

Concrete or wood sub-floor, no floor 

covering over top

#8 x 1” *

Concrete or wood sub-floor, floor 

covering up to 1/4” thick

#8 x 1” *

Concrete or wood sub-floor, floor 

covering over 1/4” and up to 1/2” thick

#8 x 1 1/4” *

Wood sub-floor, floor covering over 

1/2” and up to 1 3/16” thick

#12 x 1 3/4” *

Concrete sub-floor under floor covering  

over 1/2” thick

Must be purchased 

separately **

Wood sub-floor, floor covering  

over 1 3/16” thick

Must be purchased 

separately **

* Included with range
** Not included. Determine length based on step 3.

Attaching the bracket to a concrete floor:

• 

Drill four (4) 3/8” diameter countersink holes through any 

existing floor covering down to the concrete slab below. 

• 

Drill the 4 holes for the anchors 1 1/4” (3.2 cm) deep into the 

concrete slab using a 3/16” masonry bit. This hole length is 

longer than the anchor, but is required for proper installation. 

Clear the holes of dust and any other material. Tap each 

anchor into the hole until the anchor top is flush with the top 

of the concrete slab. Position the anti-tip bracket holes over 

the anchor holes. Insert the screws through the 4 holes in 

the base of the bracket and thread them into the anchors. Be 

sure the screw threads fully engage the anchor body. Tighten 

the screws into place. 

Attaching the bracket to a wood floor:

• 

If there is ceramic, asphalt or other hard floor covering over 

the wood below, drill 4 countersink holes to allow access to 

the wood below for drilling pilot holes.

• 

Drill 4 pilot holes into the wood floor using a drill bit (1/16” 

dia. for #8 screws, 1/8” dia. for #12 screws). Position the anti-

tip bracket holes over the holes in the floor. Insert the screws 

into the wood and tighten into place.

Installing the Anti-Tip Bracket on the wall

1.  To use the wall mount option, the range front panel must not 

be more than 26 1/4” from the wall and the bracket screws 

must be able to thread into the base plate inside the wall 

behind. The notches on the sides of the bracket indicate the 

minimum required height of the base plate inside the wall and 

that any floor covering is not too thick for proper screw thread 

engagement.

Screws attached 

to sub-floor below 

floor covering

Sub-floor

Concrete 

anchors shown, 

do not use for 

wood sub-floor

Floor 

covering

Anti-tip 

bracket

Содержание Renaissance RR30NFS

Страница 1: ...Installation Instructions Renaissance Electric Range Part No 105910 Rev A Models RR30NS RR30NS C RR30NFS RR30NFS C RR30NIS and RR30NIFS with induction cooktop...

Страница 2: ...al number are printed on the product data label Dacor Customer Service Phone 800 793 0093 extension 2813 U S A and Canada Monday Friday 6 00 a m to 5 00 p m Pacific Time Web site www dacor com Dacor D...

Страница 3: ...eath warning NEVER use this appliance as a space heater to heat or warm the room Doing so may result in overheating of the appliance warning NEVER cover any slots holes or passages in the oven bottom...

Страница 4: ...iance is not approved for installation in a mobile home or recreational vehicle This appliance must not be used in combination with surface countertop ventilation systems The use of an overhead hood o...

Страница 5: ...ion box or A 3 wire conduit where local code permits connected to a 3 wire junction box Suggested conduit wiring color code black white red and green Using an appliance cord A 4 wire appliance cord eq...

Страница 6: ...piece in place of a backguard A backguard may be purchased as an optional accessory Add an additional 1 16 inch to the depth dimensions above when installing a backguard on models RR30NIS and RR30NIF...

Страница 7: ...ications for minimum clearances If cabinet storage space is to be provided directly above the range the risk of personal injury may be reduced by installing a range hood The range may be installed flu...

Страница 8: ...tion Models RR30NIS and RR30NIFS Only To create a built in look on the front of the cabinet this dimension may be changed to 29 1 4 74 3 cm with the width at the notches remaining 30 1 16 This configu...

Страница 9: ...this dimension may be changed to 29 1 4 74 3 cm with the width at the notches remaining 30 1 16 This configuration is only for models RR30NIS and RR30NIFS with the side panels behind the door removed...

Страница 10: ...quired The minimum full thread depth portion of screw threaded into wood slab for wood is 3 8 1 cm and 5 8 1 6 cm for concrete See the table below to select the correct screw size Sub Floor Type Floor...

Страница 11: ...thod may not be used and the floor mounting method must be suitable or the wall must be modified so that the base plate is above the notches 4 To install the bracket place it against the wall in the m...

Страница 12: ...ng can cause an electric shock hazard and damage the appliance Dacor is not responsible for damages resulting from improper installation This range must be connected to a grounded metallic permanent w...

Страница 13: ...relief inside the box Tighten into place 6 Connect the white wire to the neutral terminal inside the box 7 Connect the black wire to the L1 power supply terminal 8 Connect the red wire to the L2 powe...

Страница 14: ...ce inside the junction box 2 Connect the white wire from the appliance to the neutral white supply wire inside the junction box 3 Connect the black wire from the appliance to the black L1 power supply...

Страница 15: ...Conduit Junction Box Connection with External Ground Separate No 10 minimum copper grounding wire Wire nut 4 places Conduit to appliance Conduit to appliance Wire nut 3 places Junction box Junction b...

Страница 16: ...onnection cont Appliance Cord Connections Where Local Code Permits warning Do not connect the green appliance wire to the neutral white supply wire unless local building codes permit 1 Remove the rang...

Страница 17: ...umper link Link removed Ground screw L2 terminal L2 terminal L1 wire L1 wire White wire White wire Green wire L2 wire L2 wire Strain relief Strain relief 3 Wire Appliance Cord Connection Where Local C...

Страница 18: ...loor to the countertop and adjust the leveling legs as required to position the top frame at the desired height based on the cabinet and countertop installation 2 Carefully slide the range into positi...

Страница 19: ...e troubleshooting steps Verify that power is being supplied to the range Check the electrical connections to ensure that the installation has been completed correctly Repeat the above tests If the app...

Страница 20: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Отзывы: