background image

All specifications subject to change without notice.

Phone: (800) 793-0093

www.dacor.com

PLANNING

GUIDE

RNRP36G, RNRP48G

Renaissance

 

36” and 48” Wide 

All Gas Ranges

Document # PG05-012

Revised 03/16/15   Page 3/3

BACK OF RANGE

GAS SUPPLY PRESSURE REQUIREMENTS

Gas 

Type

Manifold 

Pressure* (WC)

Min. Gas Supply 

Pressure (WC)

Max. Input 

Pressure

Natural

5”

6”

1/2 psi

LP

10”

11”

1/2 psi

IMPORTANT: 

The information above is for reference only. If the above data 

does not agree with the product data label, use the data on the product 

data label on top of the kick plate below the door (see the installation 

instructions for location).
The range comes from the factory with the regulator installed. Use only the 

installed regulator. The regulator inlet accommodates a 3/4” gas line. The 

range ships with a 1/2” to 3/4” adapter connected to the regulator.

ELECTRICAL REQUIREMENTS

Electrical Circuit 

Required

Total Connected 

Load

 120 Vac, 60 Hz, 15 Amp.  

grounded, dedicated, 3 prong 

electrical outlet

5.0 Amps. @120 Vac, 

60 Hz,

B

A

Range 

Model

A

B

RNRP36G

13 1/16” to 14 3/8”

(33.2 to 36.5 cm)

7 5/16”

(18.6 cm)

RNRP48G

13 1/16” to 14 3/8”

(33.2 to 36.5 cm)

4 1/4”

(10.8 cm)

ELECTRICAL AND GAS REQUIREMENTS

Отзывы: