PLANNING
GUIDE
RNRP36G, RNRP48G
Renaissance
36” and 48” Wide
All Gas Ranges
Document # PG05-012
Revised 03/16/15 Page 3/3
BACK OF RANGE
GAS SUPPLY PRESSURE REQUIREMENTS
Gas
Type
Manifold
Pressure* (WC)
Min. Gas Supply
Pressure (WC)
Max. Input
Pressure
Natural
5”
6”
1/2 psi
LP
10”
11”
1/2 psi
IMPORTANT:
The information above is for reference only. If the above data
does not agree with the product data label, use the data on the product
data label on top of the kick plate below the door (see the installation
instructions for location).
The range comes from the factory with the regulator installed. Use only the
installed regulator. The regulator inlet accommodates a 3/4” gas line. The
range ships with a 1/2” to 3/4” adapter connected to the regulator.
ELECTRICAL REQUIREMENTS
Electrical Circuit
Required
Total Connected
Load
120 Vac, 60 Hz, 15 Amp.
grounded, dedicated, 3 prong
electrical outlet
5.0 Amps. @120 Vac,
60 Hz,
B
A
Range
Model
A
B
RNRP36G
13 1/16” to 14 3/8”
(33.2 to 36.5 cm)
7 5/16”
(18.6 cm)
RNRP48G
13 1/16” to 14 3/8”
(33.2 to 36.5 cm)
4 1/4”
(10.8 cm)
ELECTRICAL AND GAS REQUIREMENTS