background image

13

Installation Instructions

Verifying Proper Operation

Before operating the range, read the accompanying use and 

care manual completely. It contains Important safety, service and 

warranty information.
1.  Before beginning the test procedure, ensure that all cooktop 

control valves are in the 

OFF

 position, and all burner rings, 

burner caps, and grates are properly positioned on the 

cooktop frame. 

2.  Turn on the gas supply at the shut-off valve.
3.  Connect the power cord to the electrical outlet. When the 

range is first connected, the oven indicator light flashes on 

and off for about 10 seconds while the range’s circuitry starts 

up. Wait for the light to stop flashing before going to step 4.

4.  Test one of the burners by pushing the knob in and turning 

it counterclockwise to the 

HIGH

 position. It may take up to 

four seconds for ignition to occur, at which time the ignitor will 

stop sparking. If ignition does not occur within four seconds, 

turn off the knob, wait for at least five minutes to allow any 

gas to dissipate, then repeat the ignition test. After ignition, 

rotate the control knob counterclockwise from 

HIGH

 to 

LOW

 

to adjust the flame height progressively. When the range is 

installed properly, the flame will 

be steady and quiet. It will also 

have a sharp, blue inner cone that 

will vary in length proportional to 

the burner size. Dacor’s Smart 

Flame™ feature reduces the flame 

under the grate fingers to increase 

grate life. If the range is equipped 

for use with LP gas, the ends of 

the flame may be yellow at the 

tips, which is normal.

5.  Turn the control knob to the 

OFF

 position. 

6.  Repeat the ignition test for all remaining burners. 

After testing all the cooktop burners, turn them off.

7.  Open the oven door(s). Test the oven light(s) by 

turning on the light switch(s) on the control panel.

8.  Turn on the convection fan switch(s). You should hear the 

convection fan, located behind the screen at the back of the 

oven, come on.

9.  With the oven door open, turn the oven control knob to the 

400 degree position. Both the knob itself and the oven ON 

indicator light next to the knob should illuminate. Within 60 

seconds you should hear the bake burner ignite below the 

oven floor. It should begin to give off heat.

10.  Turn the oven control knob to the BROIL position. The bake 

burner should turn off. Both the oven control knob and the 

oven ON indicator light should be illuminated.

11.  Within 60 seconds the IR burner on the ceiling of the oven 

should ignite and begin to give off heat.

12.  Turn the oven knob to the “OFF” position. On model 

RNRP48G, test both ovens.

If the range does not operate properly, follow these 

troubleshooting steps:
1.  Verify that power and gas are supplied to the range.
2.  Check the electrical connections and gas supply to ensure 

that the installation has been completed correctly.

3.  Repeat the burner ignition test and/or oven test.
4.  If the appliance still does not work, contact Dacor Distinctive 

Service at (800) 793-0093 ex. 2822. Do not attempt to repair 

the appliance yourself. Have the model and serial numbers 

available when you call. See inside cover for location.

Dacor is not responsible for the cost of correcting problems 

caused by a faulty installation.

Removing the Range for Service

1.  Turn the gas supply valve to the off position.
2.  Disconnect the power cord from the electrical outlet.
3.  Pull the range out from the wall

Reinstalling the Range After 

Service

1.  Push the range into operating position, making sure the anti-

tip bracket is engaged (see page 10).

2.  Connect the power cord to the electrical outlet.
3.  Turn the gas supply valve to the on position.

Installation Checklist

 

WARNING

• 

To ensure a safe and proper installation, the following 

checklist should be completed by the installer to ensure 

that no part of the installation has been overlooked.

• 

Proper installation is the responsibility of the homeowner. 

The importance of proper installation of your Dacor range 

cannot be overemphasized.

 

Has the plastic coating been peeled off the outside of the 

range? Have all packaging materials been removed from 

inside the oven?

 

Are all leveling legs extended down to make contact with the 

floor? Is the unit level? See page 10.

 

Is the range secured in place with the provided anti-tip 

bracket and foot according to these instructions? See pages 

6 and 10.

 

Has the gas supply inlet pressure been measured to ensure 

that it does not exceed the maximums stated in these 

instructions. See page 3.

 

Is the range connected to the gas supply according to these 

instructions and in accordance with all applicable codes? Did 

the installer check the gas supply for leaks?

 

Is the oven door properly installed according to these 

instructions? See page 10.

 

Have the burner knobs been installed in the proper locations? 

See page 11.

 

Are the burners assembled and grates properly installed 

according to these instructions? See page 12.

 

Has proper operation been verified? Has the warranty 

been activated on-line or the warranty card been filled out 

completely and mailed?

OFF Icon

Normal Flame

Содержание Renaissance RNRP36G

Страница 1: ...structions Renaissance Gas Range Part No 108531 Rev B THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITIONS OF ANSI Z21 1 UL858 AND UL60730 1 STANDARDS FOR HOUSEHOLD APPLIANCES Models RNRP36GS RNRP48GS ...

Страница 2: ...the Range After Service 13 Installation Checklist 13 Customer Service Information If you have questions or problems with installation contact your Dacor dealer or the Dacor Customer Service Team For repairs to Dacor appliances under warranty call the Dacor Distinctive Service line Whenever you call have the model and serial number of the appliance ready The model and serial number label is located...

Страница 3: ...is appliance as a space heater to heat or warm the room Doing so may result in carbon monoxide poisoning and overheating of the appliance WARNING NEVER cover any slots holes or passages on the inside or outside of the range or cover an entire rack with materials such as aluminum foil Doing so blocks air flow through the oven and may cause carbon monoxide poisoning Aluminum foil linings may also tr...

Страница 4: ...ended in the area around the range Do not allow children to play with the controls pull on the handle s or touch other parts of the range Do not store items of interest to children on top of or above the range Children could be burned or injured while climbing on the appliance Do not attempt to use this appliance in the event of a power failure Clean the cooktop thoroughly before operating it for ...

Страница 5: ...quirements The installation of this appliance must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 Be certain that the appliance being installed is correct for the gas service provided natural gas or LP gas Also if operating the range at an altitude above 4000 ft 1219 m make sure it is equipped for high altitude operation Refer to the r...

Страница 6: ... 26 66 0 cm 24 61 0 cm 1 1 4 3 2 cm to 1 1 16 2 7 cm to cooking surface top of grates from top of trim Finished side panel X 24 61 0 cm Cabinet face lines up with back of control panel Product tolerances 1 16 1 6 mm Product Dimensions The backguard is available in two heights 3 inches standard and 9 inches optional Width RNRP36G 35 7 8 91 1 cm RNRP48G 47 7 8 121 6 cm View of Range Installed Side V...

Страница 7: ...etween the gas inlet and the range for the purpose of turning on or shutting off gas to the appliance The installation must allow for the following Access to the gas shut off valve when the unit is installed Access to the electrical outlet when the range is in place The gas supply piping and shut off valve and the electrical outlet must be located so they do not interfere with the range when it is...

Страница 8: ...l the optional 9 inch backguard before making the range gas and electrical connections Install it according the installation instructions included with the backguard kit Approved backguard kits Model Description APB36D9 9 inch high backguard for range model RNRP36G APB48D9 9 inch high backguard for range model RNRP48G Install the Anti Tip Bracket and Foot Locate the anti tip bracket included in th...

Страница 9: ...w threaded into wood slab for wood is 3 8 1 cm and 5 8 1 6 cm for concrete See SCREW SIZE TABLE to select the correct screw size Attaching the bracket to a concrete floor Drill four 4 3 8 diameter countersink holes through any existing floor covering down to the concrete slab below Drill the 4 holes for the anchors 1 1 4 3 2 cm deep into the concrete slab using a 3 16 masonry bit This hole length ...

Страница 10: ...nsions on page 5 and the actual cabinet cutout dimensions used for the installation Determine and mark the required position of the anti tip bracket based on the diagram above Push the bracket up against the wall in the mounting location Using a pencil make a dot next to the notches on both sides of the bracket Determine if the base plate is as high at the notches by drilling test holes into the w...

Страница 11: ...ected from the gas supply piping during any pressure testing exceeding 1 2 psi 3 5 kPa The range must be isolated from the gas supply piping by closing the shut off valve during any pressure testing at or below 1 2 psi 3 5 kPa Check all gas lines for leaks as instructed to avoid a fire or explosion hazard Do not use a flame to check for leaks NOTE The gas pressure regulator is pre set at the facto...

Страница 12: ...he notch on the bottom of each hinge rests on top of the lower lip of each hinge receptacle before attempting to open the oven door Rotate the hinge locks toward the front of the range immediately after installation of the door 1 Grasp the oven door on opposite sides and hold it at a 15 angle from the front of the oven Slide the hinges into the hinge openings resting the bottom of the hinge arms o...

Страница 13: ...e 3 different types of knobs supplied with the range The oven knob s has have the word BROIL on them The knobs for the middle burners have the words MAX GRIDDLE on them 1 Put the oven knob s A on the oven valve shaft s as shown 2 Put the knobs with the words MAX GRIDDLE on them B onto the center burner valve shafts as shown 3 Put the remaining knobs C on the outer valve shafts as shown Icons on Ce...

Страница 14: ... pieces are properly seated Gently set the grates on top of the spill tray Put the legs of each grate inside the corresponding dimples SimmerSear Burner Installation Standard Burner Installation STEP 1 Install burner head Put locating tab in keyed hole STEP 1 Put burner ring on top of head STEP 2 Install burner ring Line up ring tabs with head slots STEP 2 Turn ring until it drops into place STEP ...

Страница 15: ...the IR burner on the ceiling of the oven should ignite and begin to give off heat 12 Turn the oven knob to the OFF position On model RNRP48G test both ovens If the range does not operate properly follow these troubleshooting steps 1 Verify that power and gas are supplied to the range 2 Check the electrical connections and gas supply to ensure that the installation has been completed correctly 3 Re...

Страница 16: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com ...

Отзывы: