7
Note 2
F
G
2
Cabinet/countertop depth is at discretion of customer but
cabinet face MUST NOT protrude further than rear of front
panel, see product dimensions.
3
Consult local code for exact location requirements.
1
Vertical from range grate level to combustible overhead
surface; if installing an overhead vent hood, also check
hood specifications for minimum required clearances.
4
Vertical from grate level to combustible surface.
Non-combustible
surface along back wall
recommended
10” (25.4 cm) min.
to combustible side
walls above the range
(both sides)
30” (76.2 cm)
min.
1
37 1/2”
(95.3 cm)
max.
13” (33.0 cm)
max.
5
15” (38.1 cm)
min.
4, 5
5
This specification does not apply for cabinets more
than a horizontal distance of 10” (25.4 cm) from the
edge of the range.
Suggested
location of
utilities
3
Grate
level
• For safe operation, maintain all specified maximum and minimum
dimensions and clearances.
• The range should be installed away from drafts (open doors/windows,
home ventilation).
• Do not install cabinets directly above the range, or reduce risk of fire and
injury (from reaching over an active cooktop) by installing a range hood
that projects horizontally at least 5” beyond the cabinet bottoms.
• You may place the range against the rear wall. Dacor recommends
installing a non-combustible material on the rear wall between the range
and vent hood. Installation of non-combustible material directly behind
the range is not needed, but seal any openings in the wall behind the
range or in the floor beneath it.
Cabinet Layout
Gas and Electrical Service
• The shaded area in the above graphic is the suggested location of the
gas inlet and electrical outlet. If replacing the range, existing utilities
may be used if they do not interfere with the new range’s placement.
Check building codes for permissible gas-valve locations.
• An external, manual shut-off valve must be installed between the gas
inlet and range so gas to the range can be turned on/off.
• Location of the gas-supply piping and shut-off valve, and the
electrical outlet must not interfere with placement of the range.
• The gas valve and electrical outlet must be accessible without moving
the range.
• The gas shut-off valve must be located so the range can be pulled out
for service/cleaning without disconnecting the conduit.
Cutout tolerances: +1/16” (+1.6 mm), -0
unless otherwise stated
G
10" (25.4 cm) min.
to combustible side
walls
above
the range
(on both sides)
non-combustible
rear wall (recommended)
H
Backsplash
3/8" (1.0 cm)
min. for downdraft cap
clearance
J
Note 2
Planning the Installation
HGR30S: DIMENSIONS
F
G
H
I
J
36”* (91.4 cm);
30”** (76.2 cm)
30”**
(76.2 cm)
27 1/2”
(69.9 cm)
30 7/8”
(78.4 cm)
3 ”
(7.62 cm)
*recommended; **minimum
Callout
Description
1
Vertical from top of grate to combustible overhead surface. NOTE: If installing a vent hood, check
hood specifications for minimum required clearances.
2
Cabinet/countertip depth is at discretion of owner, but cabinet face must NOT extend beyond rear
of front panel (see Product Dimensions, Pg. 6).
3
Consult local code for exact location requirements.
4
Vertical from top of grate to combustible surface.
5
Does not apply for cabinets more than a horizontal distance of 10” (25.4 cm) from edge of range.
Approved Downdraft
Range
HGR30P
Downdraft
MRV3015-ER