Electrical Specifications

 WARNING

The electrical service to the range hood should be 

installed only by a licensed electrician.

It is the owner’s responsibility to ensure that the electrical 

connection of this appliance is performed by a qualified 

electrician. The electrical installation, including minimum 

supply wire size and grounding, must be in accordance 

with the National Electric code ANSI/NFPA* (or latest 

revision) and local codes and ordinances.
* A copy of this standard may be obtained from:
National Fire Protection Association  

1 Batterymarch Park 

Quincy, Massachusetts 02269-9101
Connect the hood to a junction box supplied by a 120 

Vac, 60 Hz dedicated, grounded, 3-wire (hot, neutral, 

ground) circuit protected by a 15 Amp. circuit breaker 

or time delay fuse. It must be installed a minimum of 17 

inches above the bottom of the hood.

Planning the Duct Work

 WARNING

To reduce the risk of fire and to properly exhaust air, 

• 

be sure to duct air outside the house or building. Do 

not vent exhaust air into spaces within walls or ceil-

ings or into attics, crawl spaces or garages.
To prevent combustion by-products smoke or odors 

• 

from entering the home and to improve efficiency, 

tape all duct joints securely.
Do not exhaust more than one vent into a single 

• 

duct run.
TO REDUCE THE RISK OF FIRE, USE ONLY 

• 

METAL DUCTWORK.

DO NOT

• 

 install an additional in-line or external 

blower to increase the length of the duct run. Even 

small differences between blower air flow rates can 

greatly reduce the air draw of the hood.

All duct work materials (including screws and duct 

• 

tape) must be purchased separately by the customer.
The hood exhaust connects to an 8-inch round duct. 

• 

You can increase the duct size over the duct run if 

desired. To prevent a back draft, never decrease the 

duct size over the run. If existing duct work is smaller 

than 8 inches in diameter, remove it and replace it 

with 8-inch duct work.
Do not rely on tape alone to seal duct joints. Fasten 

• 

all connections with sheet metal screws and tape all 

joints with certified silver tape or duct tape. Use sheet 

metal screws as required to support the duct weight.
To prevent back-drafts, a damper at the duct outlet 

• 

may  also be required.

Installation Specifications

When planning new 

• 

duct work, always look 

for the shortest, most 

direct route to the out-

side. Venting can be 

done through the roof 

or directly through the 

back wall to the out-

side as shown.
Make sure duct work 

• 

does not interfere with 

floor joists  or wall 

studs.

Calculating the Maximum Duct Run Length

The maximum straight duct length for the hood is 50 feet. 

To determine the actual maximum duct run, subtract the 

equivalent length of each elbow, transition and cap from 

50 feet.

EQUIVALENT LENGTHS 

Piece

Subtract

Piece

Subtract

8” 90° elbow

7 feet

10” 90° elbow

5 feet

8” 45° elbow

3 feet

10” 45° elbow

2 feet

3¼” X 10”

to round 90° 

transition

25 feet

3¼” X 10” to

8”/10” round 

transition

4 feet

Roof cap

*

Wall cap with 

damper

*

* The equivalent lengths of roof and wall caps vary with 

model and configuration. For equivalent length, contact 

the manufacturer or a qualified HVAC specialist.

Duct Work Design Tips

Wherever possible, reduce the number of transitions 

• 

and turns to as few sharp angles as possible. Two 

staggered 45° angles are better than one 90°.
Keep turns as far away from the hood exhaust as 

• 

possible, and as much space between bends as pos-

sible.
For best performance, use round duct instead of rect-

• 

angular, especially when elbows are required.
If multiple elbows are used, try to keep a minimum of 

• 

24 inches straight duct between them. Avoid “S” or 

“back to back” use of adjacent elbows.
In regions where the weather gets extremely cold, 

• 

use thermal breaks, such as a short section of 

non-metallic duct, to avoid indoor heat loss. Locate 

the break as close as possible to the outside pass 

through point.
Do not use flexible metal duct.

• 

DO NOT

• 

 use duct work that is smaller in cross-

sectional area than the recommended size duct (8” 

round).

Содержание PREFERENCE PHW30

Страница 1: ...Installation Instructions Preference Wall Mount Range Hood Models PHW30 and PHW36 Part No 101745 Rev E ...

Страница 2: ... installation process Leave these installation instructions with the customer Customer Keep these installation instructions for future reference and the local electrical inspector s use If You Need Help If you have questions or problems with installation contact your Dacor dealer or the Dacor Customer Service Team For repairs to Dacor appliances under war ranty call the Dacor Distinctive Service l...

Страница 3: ...NG Use this unit only in the manner intended by the manufacturer If you have questions contact the a manufacturer Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting b means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the serv...

Страница 4: ...urfaces often to prevent grease fires and maintain performance If the cooktop and range hood are near a window use an appropriate window treatment Avoid long drapes or other window coverings that could blow over the cooktop and hood resulting in a fire hazard Always run the blower whenever the cooktop is operating Never leave the range or cooktop unattended when a burner or element is in use Boil ...

Страница 5: ...your local building department for further information The minimum installed distance from the rear of blower unit base to the cooktop surface must be no less than 30 inches 76 2 cm 26 inches 66 0 cm for an electric cooktop The minimum specified distance may be higher for the particular range or cooktop in use Check the manufacturers specifica tions for the cooktop or range Product Dimensions Tole...

Страница 6: ...eplace it with 8 inch duct work Do not rely on tape alone to seal duct joints Fasten all connections with sheet metal screws and tape all joints with certified silver tape or duct tape Use sheet metal screws as required to support the duct weight To prevent back drafts a damper at the duct outlet may also be required Installation Specifications When planning new duct work always look for the short...

Страница 7: ...t literature Order the correct size and part number see page 3 for more information A A B C C B D D E F G G H H F E 8 20 cm warning Do not install the range hood unless the power supply provided meets the required Electrical Specifications see page 4 Observe all governing codes and ordinances during installation Contact your local building department for fur ther information A qualified technician...

Страница 8: ...the chimney mounting bracket against the ceil 8 ing and attach it using two included 1 1 2 screws Installing the Blower Mounting Bracket Find the mounting bracket template in the shipping 1 box Put the template against the wall and line up the horizontal line drawn on the wall with the horizontal line on the template Line up the vertical line drawn on the wall with the 2 center line on the templat...

Страница 9: ...ck or masonry Drill five 5 16 X 1 1 2 holes in the locations marked Insert five of the provided wall anchors into the five holes The anchors provided are for attaching the hood to masonry or brick only Attach the blower assembly mounting bracket and the 6 L brackets securely to the wall 5 places Installation Instructions Duct through ceiling option 1 Duct through back wall option 2 End of duct eve...

Страница 10: ...per flaps on the top of the hood from opening Inside the exhaust outlet on the top of the blower 1 assembly there are metal or plastic damper flaps The flaps close to help prevent back drafts when the blower is turned off Remove the shipping tape and make sure the flaps open and close freely before pro ceeding Lift the blower assembly up and put the mounting 2 hole on the top over the mounting bra...

Страница 11: ...k or fire hazard make sure the power supply at the fuse or junction box is turned off before proceeding with final installation Improper connection of the hood electrical wiring may create an electric shock or fire hazard and may result in damage to the hoods electrical system Do not ground the hood to the neutral white power supply wire Connect the hood ground wire to a separate properly grounded...

Страница 12: ...e bottom of the blower assembly Insert all four thumb screws into the bottom of the 4 glass and tighten into place Installing the Chimney Cont Carefully put the chimney over the blower assembly 5 taking care not to scratch the surfaces Make sure the wiring is tucked in behind the chimney Lock the tabs inside the chimney bottom into the slots 6 on the bottom of the blower assembly Slide the top of ...

Страница 13: ...card filled out completely and mailed Verifying Proper Operation Turn on power at the junction or fuse box 1 If the control panel is not lit turn on the main power 2 switch located next to the light fixture on the under side of the hood Touch the light key Verify that all the lights come on 3 Touch the light key again to turn the lights off 4 Touch the blower 5 key once and release Verify that one...

Страница 14: ...12 Notes ...

Страница 15: ......

Страница 16: ...Dacor 600 Anton Blvd Suite 1000 Costa Mesa CA 92626 Phone 800 793 0093 Fax 626 403 3130 www Dacor com ...

Отзывы: