Dacor PREFERENCE PHW30 Скачать руководство пользователя страница 2

Installation Instructions ............................................... 5

Verify the Package Contents ....................................... 5

Installing the Chimney Mounting Bracket ................... 6

Installing the Duct Work .............................................. 7

Hanging the Blower Assembly .................................... 8

Electrical Connection .................................................. 9

Installing the Chimney (Cont.) ................................... 10

Installing the Hood .................................................... 10

Verifying Proper Operation .........................................11

Installation Checklist ..................................................11

Notes............................................................................ 12

Table of Contents

Before You Begin...

Customer Service Information

Important Safety Instructions ..................................... 1

Important Information About Safety Instructions ......... 1

General Safety Precautions ........................................ 2

Installation Specifications  .......................................... 3

Product Dimensions .................................................... 3

Operating Specifications ............................................. 3

Planning the Location ................................................. 3

Electrical Specifications .............................................. 4

Planning the Duct Work .............................................. 4

All specifications subject to change without notice. Dacor

 

assumes no liability for changes to specifications.

© 2008 Dacor, all rights reserved.

Important:

Installer:

• 

 In the interest of safety and to minimize problems, read these installation instructions completely and 

carefully before you begin the installation process. Leave these installation instructions with the customer.

Customer:

• 

 Keep these installation instructions for future reference and the local electrical inspector’s use.

If You Need Help...

If you have questions or problems with installation, contact your Dacor dealer or 

the Dacor Customer Service Team. For repairs to Dacor appliances under war-

ranty call the Dacor Distinctive Service line. Whenever you call, have the model 

and serial number of the appliance ready. The model and serial number are 

printed on the appliance data label (see below for location). Remove the filter(s) 

to view the label.

Dacor Customer Service Team

 

Phone:  (800) 793-0093 (U.S.A. and Canada) 

 

Monday — Friday 6:00 

a

.

m

.

 to 5:00 

p

.

m

.

 Pacific Time

 

Web site:  www.Dacor.com

Dacor Distinctive Service (for repairs under warranty only)

 

Phone: (877) 337-3226 (U.S.A. and Canada) 

 

Monday — Friday 6:00 

a

.

m

.

 to 4:00 

p

.

m

.

 Pacific Time

Product Data Label

The product data label contains the model and serial number information 

• 

and the electrical requirements.
The label is located inside the hood chassis, behind the left filter as you 

• 

face the front. Remove the filter to view it.

Содержание PREFERENCE PHW30

Страница 1: ...Installation Instructions Preference Wall Mount Range Hood Models PHW30 and PHW36 Part No 101745 Rev E ...

Страница 2: ... installation process Leave these installation instructions with the customer Customer Keep these installation instructions for future reference and the local electrical inspector s use If You Need Help If you have questions or problems with installation contact your Dacor dealer or the Dacor Customer Service Team For repairs to Dacor appliances under war ranty call the Dacor Distinctive Service l...

Страница 3: ...NG Use this unit only in the manner intended by the manufacturer If you have questions contact the a manufacturer Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting b means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the serv...

Страница 4: ...urfaces often to prevent grease fires and maintain performance If the cooktop and range hood are near a window use an appropriate window treatment Avoid long drapes or other window coverings that could blow over the cooktop and hood resulting in a fire hazard Always run the blower whenever the cooktop is operating Never leave the range or cooktop unattended when a burner or element is in use Boil ...

Страница 5: ...your local building department for further information The minimum installed distance from the rear of blower unit base to the cooktop surface must be no less than 30 inches 76 2 cm 26 inches 66 0 cm for an electric cooktop The minimum specified distance may be higher for the particular range or cooktop in use Check the manufacturers specifica tions for the cooktop or range Product Dimensions Tole...

Страница 6: ...eplace it with 8 inch duct work Do not rely on tape alone to seal duct joints Fasten all connections with sheet metal screws and tape all joints with certified silver tape or duct tape Use sheet metal screws as required to support the duct weight To prevent back drafts a damper at the duct outlet may also be required Installation Specifications When planning new duct work always look for the short...

Страница 7: ...t literature Order the correct size and part number see page 3 for more information A A B C C B D D E F G G H H F E 8 20 cm warning Do not install the range hood unless the power supply provided meets the required Electrical Specifications see page 4 Observe all governing codes and ordinances during installation Contact your local building department for fur ther information A qualified technician...

Страница 8: ...the chimney mounting bracket against the ceil 8 ing and attach it using two included 1 1 2 screws Installing the Blower Mounting Bracket Find the mounting bracket template in the shipping 1 box Put the template against the wall and line up the horizontal line drawn on the wall with the horizontal line on the template Line up the vertical line drawn on the wall with the 2 center line on the templat...

Страница 9: ...ck or masonry Drill five 5 16 X 1 1 2 holes in the locations marked Insert five of the provided wall anchors into the five holes The anchors provided are for attaching the hood to masonry or brick only Attach the blower assembly mounting bracket and the 6 L brackets securely to the wall 5 places Installation Instructions Duct through ceiling option 1 Duct through back wall option 2 End of duct eve...

Страница 10: ...per flaps on the top of the hood from opening Inside the exhaust outlet on the top of the blower 1 assembly there are metal or plastic damper flaps The flaps close to help prevent back drafts when the blower is turned off Remove the shipping tape and make sure the flaps open and close freely before pro ceeding Lift the blower assembly up and put the mounting 2 hole on the top over the mounting bra...

Страница 11: ...k or fire hazard make sure the power supply at the fuse or junction box is turned off before proceeding with final installation Improper connection of the hood electrical wiring may create an electric shock or fire hazard and may result in damage to the hoods electrical system Do not ground the hood to the neutral white power supply wire Connect the hood ground wire to a separate properly grounded...

Страница 12: ...e bottom of the blower assembly Insert all four thumb screws into the bottom of the 4 glass and tighten into place Installing the Chimney Cont Carefully put the chimney over the blower assembly 5 taking care not to scratch the surfaces Make sure the wiring is tucked in behind the chimney Lock the tabs inside the chimney bottom into the slots 6 on the bottom of the blower assembly Slide the top of ...

Страница 13: ...card filled out completely and mailed Verifying Proper Operation Turn on power at the junction or fuse box 1 If the control panel is not lit turn on the main power 2 switch located next to the light fixture on the under side of the hood Touch the light key Verify that all the lights come on 3 Touch the light key again to turn the lights off 4 Touch the blower 5 key once and release Verify that one...

Страница 14: ...12 Notes ...

Страница 15: ......

Страница 16: ...Dacor 600 Anton Blvd Suite 1000 Costa Mesa CA 92626 Phone 800 793 0093 Fax 626 403 3130 www Dacor com ...