40
PMOR30B
PMOR30R
PMOR30S
LATCH SPRING, LATCH HEAD AND DOOR PANEL
13.Release the latch spring from the tab of the latch head
and tab of the door frame.
14.Release the latch head from the door frame.
15.Now, the latch spring, latch head and door frame are
free.
Figure C-3. Door Disassembly
DOOR GLASS
16.Remove the glass stopper from the door frame by
releasing the tab of door frame.
17.At first, slide the door glass rightwards (toward the glass
stopper side), and then slide it up. And release it from the
left and lower long tabs of the door frame.
18.Release the door glass from the upper long tab of the
door frame.
19.Now, the door glass is free.
1. Disconnect the power supply cord and remove the oven
from wall and remove outer case. (Refer to procedure of
"Removal of Oven from Wall" and "Outer case Removal")
2. Open the door and block it open.
3. To discharge high voltage capacitor, wait for 60 seconds.
4. Remove the hood exhaust louver from the oven cavity by
pushing the right and left tabs of the hood exhaust louver.
(Refer to the procedure of "HOOD EXHAUST LOUVER
REMOVAL".)
5. Remove door assembly, refer to "Door Replacement".
Replacement of door components are as follows:
6. Place door assembly on a soft cloth with latches facing
up.
Note: As the engaging part of choke cover and door frame
are provided at 15 places, do not force any particular
part.
CHOKE COVER
7. Insert a putty knife (thickness of about 0.5mm) into the
gap
A
between the choke cover and door stopper and
between the choke cover and the door frame as shown
Figure C-3 to free engaging parts.
8. Pry the choke cover by inserting a putty knife in order
shown in Figure C-3.
9. Now choke cover is free from door panel and door frame.
DOOR FRAME
10.Remove six (6) screws holding the door panel and the
door handle to the door frame assembly.
11.Release the door frame assembly from the door panel.
NOTE: It is easier to release the engaging parts of the upper
or lower door hinge pin side at first.
12.Now, door frame assembly is free.
DOOR DISASSEMBLY
A
Choke Cover
Door Frame
Door Stopper
Putty Knife
latch holes and that latch head goes through center of
latch hole.
2. Deviation of door alignment from horizontal line of cavity
face plate is to be less than 1.0mm.
3. Door is positioned with its face pressed toward cavity
face plate.
4. Re-install outer case and check for microwave leakage
around door with an approved microwave survey meter.
(Refer to Microwave Measurement Procedure.)
Note: The door on a microwave oven is designed to
act as an electronic seal preventing the leakage
of microwave energy from oven cavity during
cook cycle. This function does not require that
door be air-tight, moisture (condensation)-tight
or light-tight. Therefore, occasional appearance
of moisture, light or sensing of gentle warm air
movement around oven door is not abnormal
and do not of themselves indicate a leakage of
microwave energy from oven cavity.