Electrical Connection (Continued)

Appliance Cord Connections - Where Local 

Code Permits

 WARNING

Do not connect the green appliance wire to the neutral (white) 

supply wire unless local building codes permit.

Remove the range electrical access cover from the back of 

1. 

the range.

IMPORTANT:

2. 

 If using a 4-wire connection, loosen the 

grounding screw and remove the neutral to ground jumper 

link from the terminal block. Leave the link in place for 3-wire 

connections.
Remove the conduit bracket from the bottom of the range 

3. 

electrical box.

Disassemble and remove the strain relief from the appliance 

4. 

cord (not included). Insert the tabs on the two parts of 

the strain relief into the hole on the bottom of the box and 

reassemble it so that the tabs are below the box and the 

strain relief itself is inside the box.

Slide the end of the appliance cord into the strain relief from 

5. 

the bottom of the box.
Connect the white (neutral) wire to the neutral terminal in the 

6. 

box.
Connect the L1 wire to the L1 power supply terminal in the 

7. 

box.
Connect the L2 wire to the L2 power supply terminal in the 

8. 

box.
If using a 4-wire connection, connect the ground wire to 

9. 

the grounding screw inside the box using a loop or spade 

terminal.
Tighten the strain relief so that the appliance cord is held 

10. 

snuggly in place.
Replace the range electrical access cover.

11. 

Installation Instructions

L1 terminal

L2 terminal

L2 wire

Green wire

White wire

Strain relief

Neutral terminal

Neutral to ground 

jumper link removed

Grounding screw

4-wire Appliance 

Cord Connection 

(preferred)

Remove link on  

4-wire installations

Remove conduit bracket 

before strain relief installation

Terminal block

Strain relief

Reassemble with tabs 

below and clamp above

Bottom of range  

electrical box

L2

Neutral

Ground

L1

14-50P Plug

L1 wire

Содержание Millenia DR30D

Страница 1: ...tinctive Series Range Part No 106769 Rev A THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITIONs OF UL858 CSA C22 2 No 61 ANSI Z21 1 STANDARDs FOR HOUSEHOLD COOKING APPLIANCES For use...

Страница 2: ...All specifications subject to change without notice Dacor assumes no liability for changes to specifications 2010 Dacor all rights reserved...

Страница 3: ...uilding inspector s use READ AND SAVE THESE INSTRUCTIONS DANGER IMPORTANT If you smell gas Do not use or light any appliance Do not touch any electrical switch or use any electrical devices including...

Страница 4: ...not leave children or pets alone or unattended in the area around the range Do not allow children to play with the controls pull on the handle or touch other parts of the range Do not store items of i...

Страница 5: ...s or problems with installation contact your Dacor dealer or the Dacor Customer Service Team For repairs to Dacor appliances under warranty call the Dacor Distinctive Service line Whenever you call ha...

Страница 6: ...censed electrician install a conduit junction box or electrical receptacle according to the type of wiring used Electrical Requirements Canada It is the owner s responsibility to ensure that the requi...

Страница 7: ...28 1 2 72 4 cm 24 3 8 61 9 cm 46 3 8 117 8 cm Product tolerances 1 16 1 6 mm unless otherwise stated Product Dimensions NOTE This range is NOT designed for self rimming installation or installation w...

Страница 8: ...tility connection locations An external manual shut off valve must be installed between the gas inlet and the range for the purpose of turning on or shutting off gas to the appliance The installation...

Страница 9: ...damaged or incomplete appliance The customer must report cosmetic issues within 30 days of installation Level and Adjust the Range Height Raise or lower the range to prepare for final installation Ad...

Страница 10: ...e the appliance Dacor is not responsible for damages resulting from improper installation The ground terminal or lead on the appliance must be connected to a grounded metallic permanent wiring system...

Страница 11: ...t strain relief not included 3 Slide the wires and the end of the strain relief into the hole on 4 the bottom of the range electrical box Before connecting the wires slide the strain relief nut over 5...

Страница 12: ...ect the appliance to the junction box Connect the white wire from the appliance to the neutral 2 white supply wire in the junction box Connect the black wire from the appliance to the black L1 3 power...

Страница 13: ...amp tightly on pipe Wire nut 4 places Bare metal Metal water pipe Clamps Junction box 3 Wire Connection Conduit Junction Box Connection with External Ground Insulated Pipe Jumper Connection to applian...

Страница 14: ...de the box Slide the end of the appliance cord into the strain relief from 5 the bottom of the box Connect the white neutral wire to the neutral terminal in the 6 box Connect the L1 wire to the L1 pow...

Страница 15: ...ith the appliance To verify that the appliance is compatible with the type of gas available check the product data label see page 3 for location Ranges intended for use with LP gas will have LP as a p...

Страница 16: ...door Rotate the hinge locks toward the front of the range immediately after installation of the door Grasp the oven door on opposite sides and hold it at a 15 1 angle from the front of the oven Slide...

Страница 17: ...r cap on the center of the 3 dual burner base Line up the ridge on the bottom of the cap with the pins on the center of the burner base Standard Burner Assembly Install the standard burner rings on th...

Страница 18: ...egin to heat Press the CANCEL SECURE key to stop the oven heating process NOTES If either the oven or cooktop does not operate properly follow these troubleshooting steps Verify that power and gas are...

Страница 19: ......

Страница 20: ...Dacor 600 Anton Blvd Suite 1000 Costa Mesa CA 92626 Phone 800 793 0093 Fax 626 403 3130 www Dacor com...

Отзывы: