12
Electrical Connection (Continued)
Appliance Cord Connections - Where Local
Code Permits
WARNING
Do not connect the green appliance wire to the neutral (white)
supply wire unless local building codes permit.
Remove the range electrical access cover from the back of
1.
the range.
IMPORTANT:
2.
If using a 4-wire connection, loosen the
grounding screw and remove the neutral to ground jumper
link from the terminal block. Leave the link in place for 3-wire
connections.
Remove the conduit bracket from the bottom of the range
3.
electrical box.
Disassemble and remove the strain relief from the appliance
4.
cord (not included). Insert the tabs on the two parts of
the strain relief into the hole on the bottom of the box and
reassemble it so that the tabs are below the box and the
strain relief itself is inside the box.
Slide the end of the appliance cord into the strain relief from
5.
the bottom of the box.
Connect the white (neutral) wire to the neutral terminal in the
6.
box.
Connect the L1 wire to the L1 power supply terminal in the
7.
box.
Connect the L2 wire to the L2 power supply terminal in the
8.
box.
If using a 4-wire connection, connect the ground wire to
9.
the grounding screw inside the box using a loop or spade
terminal.
Tighten the strain relief so that the appliance cord is held
10.
snuggly in place.
Replace the range electrical access cover.
11.
Installation Instructions
L1 terminal
L2 terminal
L2 wire
Green wire
White wire
Strain relief
Neutral terminal
Neutral to ground
jumper link removed
Grounding screw
4-wire Appliance
Cord Connection
(preferred)
Remove link on
4-wire installations
Remove conduit bracket
before strain relief installation
Terminal block
Strain relief
Reassemble with tabs
below and clamp above
Bottom of range
electrical box
L2
Neutral
Ground
L1
14-50P Plug
L1 wire