background image

i

nsTallaTion

 s

peCifiCaTions

V

eRifying

 

The

 p

aCkage

 

C

onTenTs

Verify that all required components have 
been provided. If any item is missing or 
damaged, please contact your dealer 
immediately. Do not install a damaged or 
incomplete appliance.
•  Use & Care Manual
•  Ignitor Cleaning Kit
•  Broiler Pan/Grill
•  Anti-tip Bracket (selected models)
•  Grate/Burner Cap Packs
•  Griddle
•  Burner Rings
•  Wok Ring
•  Simmerplate
•  Spatula
•  Stainless Steel Cleaner
•  Pry Stick

Dacor

®

Model No.

Electrical

Circuit

Required

Total

Connected

Load

Gas 

Type

Manifold

Pressure

Min. Gas Supply

Pressure

EGR30

120VAC, 60Hz,

15A

0.75kW

(6A)

Natural

5” Water Column

6” Water Column

EGR30LP

Liquid 

Propane

10” Water Column

11” Water Column

ERD30

120/240VAC,

60Hz, 30A

4.2kW

(22A)

Natural

5” Water Column

6” Water Column

ERD30LP

Liquid 

Propane

10” Water Column

11” Water Column

ERD36

4.7kW

(24A)

Natural

5” Water Column

6” Water Column

ERD36LP

Liquid 

Propane

10” Water Column

11” Water Column

ERDE36

120/240VAC,

60Hz, 40A

7.7kW

(34A)

Natural

5” Water Column

6” Water Column

ERDE36LP

Liquid 

Propane

10” Water Column

11” Water Column

ERD48

120/240VAC,

60Hz, 50A

10.0kW

(46A)

Natural

5” Water Column

6” Water Column

ERD48LP

Liquid 

Propane

10” Water Column

11” Water Column

ERDE48

10.8kW\

(48A)

Natural

5” Water Column

6” Water Column

ERDE48LP

Liquid 

Propane

10” Water Column

11” Water Column

ERD60

120VAC, 60Hz, 

30A

4.1kW

(21A)

Natural

5” Water Column

6” Water Column

ERD60LP

Liquid 

Propane

10” Water Column

11” Water Column

Gas and Electrical Supply Requirements

It is the owner’s responsibility to ensure that the electrical 
connection of this appliance is performed by a qualified 
electrician. The electrical installation, including minimum supply 
wire size and grounding, must be in accordance with the National 
Electric code ANSI/NFPA 70-1993* (or latest revision) and local 
codes and ordinances. 

*A copy of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101

The correct voltage, frequency, and amperage must be supplied 
to the appliance from a separate, grounded, circuit that is 
protected by a properly sized circuit breaker or time delay fuse. 
Refer to the data plate, and/or the table to the right, for gas supply 
requirements.

NOTES:
1. 

The power supply must be properly polarized. 
Reverse polarity will result in continuous sparking 
of the electrodes, even after flame ignition.

2. 

If there is any doubt as to whether the power 
supply is properly polarized or grounded, have it 
checked by a qualified electrician.

3. 

Two electrical circuits and gas supplies are 
required for the ERD60.

NOTE:
The shaded areas shown in the illustrations, denote 
the location of the gas stub and the electrical 
junction box/receptacle. These are suggested 
locations. For replacement purposes, the location 
of the existing utilities may be utilized provided that 
they do not interfere with the sides or rear of the 
range. If installing the gas valve behind the range, 
verify that local building codes will permit this.

A manual shut valve must be installed in the gas piping, external 
to the appliance, for the purpose of turning on or shutting off 
gas to the appliance. Plan the location of the range and the gas 
supply to allow access to the valve when the unit is installed. 
Access to the remote circuit breaker panel/fuse box, with the 
range in place, must also be allowed for in the installation. Any 
openings in the wall behind the appliance and in the floor under 
the appliance must be sealed. 

g

as

 s

upply

 

R

equiRemenTs

e

leCTRiCal

 p

oweR

 s

upply

 

R

equiRemenTs

g

as

 & e

leCTRiCal

 R

ough

-i

n

 l

oCaTions

Check your local building codes for the 
proper method of installation. In the absence of local codes, this 
appliance should be installed in accordance with the National 
Fuel Gas Code ANSI Z223.1. Be certain that the appliance being 
installed is correct for the gas service being provided. Refer to the 
data plate located behind the inlet air cooling grill, and/or the table 
to the right, for gas supply requirements. Open the oven door and 
remove the inlet air cooling grill for access to the data plate.

 WARNING

This appliance must be installed by a licensed 
plumber or gas fitter when installed within the 
Commonwealth of Massachusetts.

 WARNING

If the gas or electric service provided does not meet 
the product specifications, do not proceed with the 
installation. Call the selling dealer, the gas supplier, 
or a licensed electrician.

Содержание Epicure ERD30

Страница 1: ...Installation Instructions Epicure Ranges For use with models ERD30 version ERD36 version ERD48 version ERD60 version EGR30 version ERDE36 version ERDE 48 version Part No 65089 Rev H...

Страница 2: ......

Страница 3: ...ce Always contact Dacor about problems or conditions you do not understand Safety Symbols Words Labels DANGER DANGER Immediate hazards which WILL result in severe personal injury or death WARNING WARN...

Страница 4: ...d is recommended for ventilation 8 This appliance must be installed with the gas pressure regulator supplied with it 9 Disconnect the electrical supply before installing or servicing the appliance 10...

Страница 5: ...Face of Control Panel Oven Door Front Edge of Bullnose Handle 9 229mm 3 79mm 15 1 4 387mm 24 610mm Backguard 9 229mm Backguard 3 76mm Backguard 19 483mm ERD EGR30 ERD60 Overall Dimensions Side View 27...

Страница 6: ...rcuit breaker or time delay fuse Refer to the data plate and or the table to the right for gas supply requirements NOTES 1 The power supply must be properly polarized Reverse polarity will result in c...

Страница 7: ...h a 25 inch 635mm overall countertop depth When installing the range into nonstandard cabinets minimum clearances shown in the diagrams on page 3 must be maintained Carefully check the location where...

Страница 8: ...m 1 4 6mm Min flat ledge Vertical non combustible surface rear wall 2 13 16 71mm ERV30 with ERD30 Slide In Self Rimming Installation using 3 Side Panels Model No AESP03 Backguard Removed Top View ERV3...

Страница 9: ...re drilled holes ERD with 9 Flue Extension 9 flue extension shown ERD48 with 9 Flue Extension 9 flue extension shown 5 Remove the backguard from its box 6 To avoid scratches place small scraps of thin...

Страница 10: ...B Connecting the Green Appliance Wire to the Neutral White Supply Wire Where Local Codes Permit 1 Connect the green and white appliance wires to the neutral white supply wire in the junction box 2 Co...

Страница 11: ...nce ground to a grounded junction box wire or grounded cold water pipe Conduit from appliance Cable from power supply Wire nut 4 places Junction box RED RED GREEN GREEN WHITE WHITE BLACK BLACK Separat...

Страница 12: ...n off the knob wait for at least 2 minutes to allow any gas to dissipate then repeat this ignition test The control knob can then be rotated counterclockwise from HIGH to LOW to adjust the flame heigh...

Страница 13: ...11...

Страница 14: ...ained herein may be copied or used in whole or in part without the express written permission of Distinctive Appliances Inc 2006 Distinctive Appliances Inc all rights reserved Specifications contained...

Отзывы: