12
Remove and discard
10.
the mounting plates
attached to both blow-
er motors.
Remove the nuts that
11.
hold the rear mount-
ing plates in place
and remove. See
below.
Attach the mounting plates removed in step 11 (rear
12.
mounting plate) to the blower motors.
Insert the opening of each blower motor assembly into
13.
the holes inside the back of the hood. The connector
on the motors must be toward the bottom of the hood.
Attach them with four (4) nuts each.
Installation Instructions
Tip the hood back, so that it lays on its back with the
4.
front pointing up.
Remove the filters from the under side of the hood.
5.
Locate the wiring harness. Cut the cable tie that takes
6.
up the slack in the cable. It is located behind the panel
on the right side inside the hood. Also cut the two (2)
cable ties that hold the wiring harness to the brace
inside the hood, on the right side. See below.
Remove and save all the nuts that hold the wiring har-
7.
ness cable clamps in place. Remove and save the
clamps.
Disconnect both wiring harness connectors from the
8.
blower motors.
While supporting each blower from below, remove the
9.
four (4) nuts that hold the blower and mounting plates
in place. Remove both blowers from the hood.
Remove cable
clamps
Remove
cable ties
Wiring harness
Connector
locations
Remove
and discard
Rear Mounting
Plate