10
Refrigerator Operation
Water Filter Performance Data
Substance Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
Chlorine Taste/Odor
Particulate Class I*
50% reduction
85% reduction
1.88 mg/L
5,700,000 #/mL
2.0 mg/L ± 10% At least
10,000 particles/mL
0.06 mg/L
69,000 #/mL**
0.05 mg/L
30,583 #/mL
96.84
98.94
>97.26
99.52
Contaminant
Reduction
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
Lead: @ pH 6.5
Lead: @ pH 8.5
0.010 mg/L
0.010 mg/L
0.153 mg/L†
0.150 mg/L†
0.15 mg/L ± 10%
0.15 mg/L ± 10%
< 0.001mg/L
< 0.001mg/L
< 0.001mg/L
< 0.001mg/L
>99.29%
>99.29%
>99.35%
>99.33%
Mercury: @ pH 6.5
Mercury: @ pH 8.5
0.002 mg/L
0.002 mg/L
0.006 mg/L
0.006 mg/L
0.006 mg/L ± 10%
0.006 mg/L ± 10%
0.0005 mg/L
0.0015 mg/L
0.0003 mg/L
0.0008 mg/L
90.91
75.93
95.70
86.22
Toxaphene
0.003 mg/L
0.015 mg/L
0.15 ± 10%
< 0.001mg/L
< 0.001mg/L
91.67%
92.97%
Atrazine
0.003 mg/L
0.009mg/L
0.009 mg/L ± 10%
< 0.002mg/L
< 0.002mg/L
75.31%
76.99%
Asbestos
99%
155 MF/L
107 to 108 fibers/L††
< 1 MF/L
< 1 MF/L
>99.99%
>99.99%
Live Cysts‡
Turbidity
>99.95%
0.5 NTU
166,500 #/L
10.7 NTU
50,000/L min.
11 ± 1 NTU
< 1 #/L‡
0.49 NTU
< 1 #/L‡
0.31 NTU
>99.99%
95.2
>99.99
>97.09%
Lindane
0.0002 mg/L
0.0002 mg/L
0.002 ± 10%
< 0.0001mg/L
0.000mg/L
96.50%
>98.72%
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C).
*
Class I particle size: >0.5 to <1 um
**
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust
†
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions
††
Fibers greater than 10 um in length
‡
Based on the use of Cryptosporidium parvum oocysts
Specifications
Water Supply:
City or well
Service Flow Rate:
.78 gpm (2.9 L/min) @ 60 psi
Water Pressure:
35 - 120 psi (241 - 827 kPa)
Water Temperature:
33° - 100°F (1° - 38°C)
It is essential that operational, maintenance and filter replacement
requirements be carried out for the product to perform as adver-
tised.
The filter monitor system measures the amount of water that
passes through the filter and alerts you to replace the filter. When
90% of the filter’s rated life is used, the yellow (Order) light comes
on. When 100% of the filter’s rated life is used, the red (Replace)
light comes on, and it is recommended that you replace the filter.
For models without filter status lights, replace the filter every 6
months. Use Dacor replacement cartridge AFF3.
This product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
This system has been tested according to ANSI/NSF 42 and 53
for reduction of the substances listed above. The concentration
of the indicated substances in water entering the system was
reduced to a concentration less than or equal to the permissible
limit for water leaving the system, as specified in ANSI/NSF 42
and 53.
® NSF is a registered trademark of NSF International.
System tested and certified by NSF International against NSF/ANSI Std 42 for the reduction of Chlorine Taste and Odor,
Particulate Class I and against NSF/ANSI 53 for the reduction of Cysts, Turbidity, Asbestos, Mercury, Lead, Benzene,
p-Diclorobenzene, Carbofuran