Dacor EORD227 Скачать руководство пользователя страница 15

 Section 4 – Troubleshooting Charts 

 

 

Page 11  

Symptoms 

 

All the voltage test points will be at the relay board. 

12) If connection is good, disconnect convection fan and measure the 

resistance directly. Resistance should be approximately 13 ohms across 
the terminals. 

13) If convection fan resistance is good, and connections are good then the 

convection fan relay is bad. Replace the relay board. Upon replacement 
do the same test again. 

14) If problem still persists, replace the display board as last resort. 

Cooling fan does not turn 
on at designated turn ON 

temperature 

1)   Start with a cold oven and run Sabbath mode to turn ON the cooling fan 

immediately. If it does not run, measure voltage on the following test 
points: 

2)   Check upper/single cooling fan, Neutral to P11 pin 2 = 120 VAC 

upper/single cooling fan. 

3)   Check lower cooling Fan, neutral to P11 pin 8 = 120VAC (lower cooling 

fan). 

4)   If no voltage for either of the above or cooling fan not running, turn OFF 

power and check continuity on following wires:  

5)   Neutral to NEUT (P6).  If no continuity, change wire or wire terminal or 

tighten neutral connection on the terminal block.   

6)    If there is continuity, check resistance on following test points: 

7)    To check upper/single cooling fan, Neutral - P11  Pin 2  = approximately 

18 ohms.  

8)    To check lower cooling fan, neutral - P11  Pin 8  = approximately 18 

ohms. 

 9)   If resistance is high, check continuity on the following wires: 

10) Check upper/single cooling fan, P11 Pin 2 to one terminal of the upper 

cooling fan. 

11) Check lower cooling fan, P11 Pin 8 to one terminal of the lower cooling 

fan. 

12) Make sure other end of the cooling fan wiring is connected to Neutral. If 

properly connected, change the wire or connector or the terminal if no 
continuity.  

13) If connection is good, disconnect the cooling fan and directly measure the 

resistance across the terminals. It should be approximately 18 ohms 
across the terminals. 

 14) If cooling fan resistance is OK and connections are good, then the 

cooling fan relay is bad. Replace the relay board. Upon replacement do 
the same test again. 

15) If problem still persists, replace the display board as last resort. 

Latch motor not running 
during Self Clean

 

1)   Start Self Clean mode and immediately check to see if the latch motor 

runs. If it does not run, measure voltage on the following test points: 

2)   Check upper/single latch motor: Neutral to P11 Pin 1 = 120 VAC 

upper/single cooling fan. 

4)   Check lower latch motor: Neutral to P11 Pin 9 = 120VAC (lower cooling 

fan) 

5)   If no voltage or latch motor not running, turn OFF power and check 

continuity on following wires:  

6)   Neutral to NEUT (P6). If no continuity, change wire or wire terminal or 

tighten neutral connection on the terminal block.  Continued… 

Convection Fan does 

not run during Preheat, 

Conv Bake, Conv Broil, 
Conv Roast (cont.) 

www.Appliantology.org

Содержание EORD227

Страница 1: ...ance Wall Oven Service Guide Models EORS127 EORS130 EORS227 EORS230 EORD227 EORD230 MORS127 MORS130 MORS136 MORS227 MORS230 MORD227 MORD230 The Life of the Kitchen Part No 106075 Rev D www Appliantolo...

Страница 2: ...Specifications subject to change without notice Dacor assumes no liability for changes to specifications 2008 Dacor all rights reserved Dacor Technical Assistance 800 353 2267 www Appliantology org...

Страница 3: ...Quick Diagnostic Test 5 Renaissance Wall Oven Quick ERC Diagnostic Test 5 Test for Upper and Single Ovens 5 Test for Lower Double Ovens 6 Section 4 Troubleshooting Charts 7 Voltage and Continuity 7 M...

Страница 4: ...Dacor Renaissance Wall Oven Service Guide vi This page intentionally left blank www Appliantology org...

Страница 5: ...not install a fuse in the neutral or ground circuit during installation A fuse in the neutral or ground circuit may result in an electrical shock hazard Do not install this appliance if the electrical...

Страница 6: ...The oven automatically locks the oven door during self cleaning Do not try to force the door open after it is locked Damage to the door and the door latch may result Before self cleaning the oven remo...

Страница 7: ...d Suite 1000 Costa Mesa CA 92626 Model and Serial Number Finding the Appliance Data Plate It can be seen through the grill located below the control panel Open the door to expose the grill On double o...

Страница 8: ...Epicure Renaissance Oven EOR Millennia Renaissance Oven MOR Configuration Single Oven S Double Oven D Width 27 Inch 27 30 Inch 30 Trim Finish Options Epicure Stainless Steel Chrome Trim SCH Black Han...

Страница 9: ...oven door and press SELF CLEAN START Check door is locked once lock icon comes on solid on display and element start cycling 9 Door latch motor disengaged Press CANCEL SECURE to cancel SELF CLEAN Chec...

Страница 10: ...n element and convection fan Press PURE CONV for lower oven 2 0 0 START When the convection element is ON measure Approx 9 10 amps are drawn Verify operation of convection fan If OK press CANCEL SECUR...

Страница 11: ...he relay board 11 If by replacing relay board problem is not fixed replace the display board as last resort No elements cycling in ALL modes 1 Make sure that the display lights up If not see No Clock...

Страница 12: ...nto preheat Once oven goes into preheat test these point of the faulty cell using voltmeter The voltages should follow the preheat cycling pattern 3 Check upper or single bake K7 L2 OUT1 BAKE 1 P19 Ch...

Страница 13: ...h check for continuity of the wires of the faulty cell 10 Check upper single broil wire BROIL 1 P15 to upper broil element terminal upper single 11 Check lower broil wire BROIL 2 P18 to lower broil el...

Страница 14: ...f it is not near 25 ohms replace convection element Convection Fan does not run during Preheat Conv Bake Conv Broil Conv Roast 1 Start with a cold oven and run any modes that will turn on the Convecti...

Страница 15: ...l P11 Pin 8 approximately 18 ohms 9 If resistance is high check continuity on the following wires 10 Check upper single cooling fan P11 Pin 2 to one terminal of the upper cooling fan 11 Check lower co...

Страница 16: ...the following test points 2 Connector P11 wire 4 to Neutral power output to light transformer 120VAC If no voltage replace relay board 3 If voltage is present check output voltage of light transforme...

Страница 17: ...CANCEL 8 5 2 CONVECTION BAKE 12 1 16 OVEN LIGHT 3 5 3 BAKE 10 1 17 START 7 5 4 START TIME 8 1 18 POUND SIGN 2 5 5 CONVECTION BROIL 12 9 19 NUMBER 1 3 1 6 BROIL 10 9 20 NUMBER 2 1 2 7 DURATION 8 9 21 N...

Страница 18: ...mbient Temperature probe open N A No Relay board open thermistor detected C35 Ambient Temperature probe shorted N A No Relay board shorted thermistor detected C41 A D Reference Readings N A No Safety...

Страница 19: ...tures above the maximum bounds U30 L30 Open RTD N A No Fatal Error Continuous A D values over maximum bounds U31 L31 Shorted RTD N A No Fatal Error Continuous A D values over minimum bounds U41 L41 A...

Страница 20: ...the number keypad enter the new calibration offset for example 25 Using the number keypad press to toggle between and Press the START key This will lock the calibration Press the CANCEL SECURE key to...

Страница 21: ...Section 7 Wiring Diagrams Page 17 Section 7 Wiring Diagrams www Appliantology org...

Страница 22: ...Dacor Renaissance Wall Oven Service Guide Page 18 www Appliantology org...

Страница 23: ...Section 7 Wiring Diagrams Page 19 www Appliantology org...

Страница 24: ...The Life of the Kitchen www Appliantology org...

Отзывы: