Dacor EORD227 Скачать руководство пользователя страница 12

Dacor Renaissance Wall Oven Service Guide 

Page 8 

Symptoms 

 

All the voltage test points will be at the relay board. 

10) L1B - L2 = 240 VAC  (Lower elements).  Continued… 

If continuity tests on previous page and above are good and voltage 
check is good, run any mode on faulty cells and check the following… 

11) K7 L2 IN1 – K7 L2 OUT1 = 0 VAC (upper/single DLB relay) 

12) K4 L2 IN2 – K4 L2 OUT2 = 0 VAC (lower DLB relay) 

If more than 100 VAC is present then the DLB relay it is not activating 
due to faulty communication with the display board. Check the 
following… 

13) Make sure P3 connector and cable are properly connected. If in doubt 

replace with new P3 cable. 

14) See if the DLB relay is damaged. If so replace relay board. 

15) If the above does not work, replace the display board as last resort. 

16) Upon replacement of wires, connectors, relay board or display board, 

rerun the above test to confirm problem is corrected.  

Bake element only is not 

cycling during preheat, 

bake, conv bake, conv 

roast, self clean, HOLD 

1)  Make sure that only the bake element is not cycling. If the other elements 

are not cycling, see 

No elements cycling in ALL modes

 on previous 

page.  

2)  Start with a cold oven and run BAKE, CONV BAKE, etc. on the faulty cell 

and make sure that oven goes to preheat mode.  If it does not go to 
preheat, cool down the oven and rerun the mode until it is cold enough to 
go into preheat. Once oven goes into preheat, test these point of the 
faulty cell using voltmeter. The voltages should follow the preheat cycling 
pattern: 

3)  Check upper or single bake, K7 L2 OUT1 – BAKE 1 (P19)  (Check upper 

BAKE ON and OFF time) 

4)  Check lower bake, K4 L2 OUT2 – BAKE 2 (P24)  (Check lower BAKE ON  

and OFF time). 

5)  If the oven is in preheat and there is no activity and no cycling indicated 

by voltmeter, then the bake relay is damaged and relay board needs to 
be replaced. Upon replacement do the same test again. 

6)  If there is activity indicated by voltmeter, then turn OFF the power and 

check the bake element resistance on the following terminals: 

7)  Check upper or single bake element, K7 L2 OUT1 - BAKE 1 (P19) = 

approximately 20 ohms. 

8)  Check lower bake element, K4 L2 OUT2  - BAKE 2 (P24) = 

approximately 20 ohms. 

9)  If resistance is high, then check for continuity of the bake element wires 

on the faulty cell: 

10) Check upper or single bake wire, BAKE 1(P19) to Upper Bake Element 

terminal. 

11) Check lower bake wire, BAKE 2(P24) to lower bake element terminal. 

12) Check upper or single bake wire, K7 L2 OUT1 to the other upper bake 

element terminal. 

13) Check lower bake wire, K4 L2 OUT2 to the other lower bake element 

terminal. 

14) If continuity is good for all wires, check to make sure the bake element 

connector is connected to the bake element terminal. If connection good,  
disconnect bake connections and directly measure the bake element 
resistance and if it not near 20 ohms, replace bake element. Continued…

No elements cycling in 

ALL modes (cont.) 

www.Appliantology.org

Содержание EORD227

Страница 1: ...ance Wall Oven Service Guide Models EORS127 EORS130 EORS227 EORS230 EORD227 EORD230 MORS127 MORS130 MORS136 MORS227 MORS230 MORD227 MORD230 The Life of the Kitchen Part No 106075 Rev D www Appliantolo...

Страница 2: ...Specifications subject to change without notice Dacor assumes no liability for changes to specifications 2008 Dacor all rights reserved Dacor Technical Assistance 800 353 2267 www Appliantology org...

Страница 3: ...Quick Diagnostic Test 5 Renaissance Wall Oven Quick ERC Diagnostic Test 5 Test for Upper and Single Ovens 5 Test for Lower Double Ovens 6 Section 4 Troubleshooting Charts 7 Voltage and Continuity 7 M...

Страница 4: ...Dacor Renaissance Wall Oven Service Guide vi This page intentionally left blank www Appliantology org...

Страница 5: ...not install a fuse in the neutral or ground circuit during installation A fuse in the neutral or ground circuit may result in an electrical shock hazard Do not install this appliance if the electrical...

Страница 6: ...The oven automatically locks the oven door during self cleaning Do not try to force the door open after it is locked Damage to the door and the door latch may result Before self cleaning the oven remo...

Страница 7: ...d Suite 1000 Costa Mesa CA 92626 Model and Serial Number Finding the Appliance Data Plate It can be seen through the grill located below the control panel Open the door to expose the grill On double o...

Страница 8: ...Epicure Renaissance Oven EOR Millennia Renaissance Oven MOR Configuration Single Oven S Double Oven D Width 27 Inch 27 30 Inch 30 Trim Finish Options Epicure Stainless Steel Chrome Trim SCH Black Han...

Страница 9: ...oven door and press SELF CLEAN START Check door is locked once lock icon comes on solid on display and element start cycling 9 Door latch motor disengaged Press CANCEL SECURE to cancel SELF CLEAN Chec...

Страница 10: ...n element and convection fan Press PURE CONV for lower oven 2 0 0 START When the convection element is ON measure Approx 9 10 amps are drawn Verify operation of convection fan If OK press CANCEL SECUR...

Страница 11: ...he relay board 11 If by replacing relay board problem is not fixed replace the display board as last resort No elements cycling in ALL modes 1 Make sure that the display lights up If not see No Clock...

Страница 12: ...nto preheat Once oven goes into preheat test these point of the faulty cell using voltmeter The voltages should follow the preheat cycling pattern 3 Check upper or single bake K7 L2 OUT1 BAKE 1 P19 Ch...

Страница 13: ...h check for continuity of the wires of the faulty cell 10 Check upper single broil wire BROIL 1 P15 to upper broil element terminal upper single 11 Check lower broil wire BROIL 2 P18 to lower broil el...

Страница 14: ...f it is not near 25 ohms replace convection element Convection Fan does not run during Preheat Conv Bake Conv Broil Conv Roast 1 Start with a cold oven and run any modes that will turn on the Convecti...

Страница 15: ...l P11 Pin 8 approximately 18 ohms 9 If resistance is high check continuity on the following wires 10 Check upper single cooling fan P11 Pin 2 to one terminal of the upper cooling fan 11 Check lower co...

Страница 16: ...the following test points 2 Connector P11 wire 4 to Neutral power output to light transformer 120VAC If no voltage replace relay board 3 If voltage is present check output voltage of light transforme...

Страница 17: ...CANCEL 8 5 2 CONVECTION BAKE 12 1 16 OVEN LIGHT 3 5 3 BAKE 10 1 17 START 7 5 4 START TIME 8 1 18 POUND SIGN 2 5 5 CONVECTION BROIL 12 9 19 NUMBER 1 3 1 6 BROIL 10 9 20 NUMBER 2 1 2 7 DURATION 8 9 21 N...

Страница 18: ...mbient Temperature probe open N A No Relay board open thermistor detected C35 Ambient Temperature probe shorted N A No Relay board shorted thermistor detected C41 A D Reference Readings N A No Safety...

Страница 19: ...tures above the maximum bounds U30 L30 Open RTD N A No Fatal Error Continuous A D values over maximum bounds U31 L31 Shorted RTD N A No Fatal Error Continuous A D values over minimum bounds U41 L41 A...

Страница 20: ...the number keypad enter the new calibration offset for example 25 Using the number keypad press to toggle between and Press the START key This will lock the calibration Press the CANCEL SECURE key to...

Страница 21: ...Section 7 Wiring Diagrams Page 17 Section 7 Wiring Diagrams www Appliantology org...

Страница 22: ...Dacor Renaissance Wall Oven Service Guide Page 18 www Appliantology org...

Страница 23: ...Section 7 Wiring Diagrams Page 19 www Appliantology org...

Страница 24: ...The Life of the Kitchen www Appliantology org...

Отзывы: