Elecronic Diagnostics
Page 19
When the ERC/Clock Control is programmed into any cooking mode, the
ERC/Clock control sends 22-24 volts DC into the relay board to power that
function. For example: if the lower oven is programmed into a bake cycle,
the ERC Clock control would send 2DCV to the Lower Oven relay board to
close the bake relay. To set a volt meter to read DCV, insert the test leads
into the rear of the wire harness that plugged into the back of the ERC/
Clock control at J-6 pin wire location 10-3. Then program the lower oven
into bake. Voltage should be 22-24 VDC.
Other test points shown below:
Bake
10-3
Broil
10-2
Convection Element 10-4
Convection Fan
10-9
Latch Motor
10-1