7
Installation Requirements
NOTE:
Gas and electrical connections may only be routed through
the bottom of the cooktop when installed with a raised vent.
Non combustible rear
wall recommended
10” (254 mm) Min. to
combustible wall
above countertop,
both sides
Cabinet face
below countertop
overhang
3/8” (10 mm) Min.
countertop overhang
2 5/8”
(67 mm)
Hole 1/2” dia. (13 mm),
2 places, through platform
for hold down bolts
1/2” (13 mm)
countertop
overhang
1” thick mounting platform Min.
Open to below to allow for raised
vent, gas and electrical connections
Countertop
Countertop
1/2” (13 mm)
countertop
overhang
2” (51 mm)
1” (25 mm)
11 7/16”
(291 mm)
15”
(381 mm)
24 5/8”
(625 mm)
CL
D
D
E
B
CL
CL
CL
Stiffener
Cabinet face
Control panel
Countertop
Dacor approved
raised vent
IMPORTANT: See raised vent
installation instructions for
duct system layout/planning
EG366 or EG486 cooktop
3/8” Min. (10 mm)
space behind
raised vent
chassis to clear
stiffener
3/8” Min. (10 mm)
flat countertop overhang
required behind cutout
Minimum
countertop
height:
30 1/4"
(768 mm)
Cabinet/Countertop Cutout Dimensions with Raised Vent - Top View
Cabinet/Countertop with Raised Vent - Side View